Evaluation of a Temperature/Humidity Data Logger for the Usage in Cattle Barns
Sensors · 05.11.2024 · 24 (22) · 7117
DOI: 10.3390/s24227117 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 05.11.2024. Verfasst von Malina Flessner und 4 weiteren Autor:innen. Beteiligte Einrichtung: Veterinary Systems Transformation and Sustainability, Clinical Department Farm Animals and Food System Science, University of Veterinary Medicine Vie…. Hauptthemen laut MEDLINE: Humidity, Temperature. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Agriculture, Forestry, Regions and Water Management as part of the departmental research program via dafne.at., Federal Ministry of Agriculture, Forestry, Regions, and Water Management (BML).
Abstract (Originalsprache)
Climate change is a worldwide problem that is manifested in livestock farming with a decrease in animal health and welfare and economic losses due to heat stress. Therefore, a precise and continuous recording of the barn climate is essential to be able to implement actions at a certain threshold. The aim of this study was to evaluate a logger for temperature and humidity (Kestrel Drop D2) marketed for on-farm use in comparison to various other temperature/humidity data loggers under field conditions. Four different sensors were used and placed in different settings in cattle barns to correlate temperature and humidity measurements. Data were recorded for over a year in total. The data were very highly correlated. Furthermore, the area under the curve for the evaluated logger in comparison to the other ones was 0.99 to 1.0, using a temperature–humidity index cut-off of 72, often set to define heat stress. In conclusion, the evaluated logger performed equally well as the other used devices. For on-farm use, it is suitable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Veterinary Systems Transformation and Sustainability, Clinical Department Farm Animals and Food System Science, University of Veterinary Medicine Vienna, Veterinaerplatz 1, 1210 Vienna, Austria.
ORCID-Profile: Malina Flessner, Felix König, Christian Guse, Michael Iwersen, Daniela Klein-Jöbstl
Förderung
- Federal Ministry of Agriculture, Forestry, Regions and Water Management as part of the departmental research program via dafne.at.
- Federal Ministry of Agriculture, Forestry, Regions, and Water Management (BML)
Zitieren
APA
Flessner, M., König, F., Guse, C., Iwersen, M., & Klein-Jöbstl, D. (2024). Evaluation of a Temperature/Humidity Data Logger for the Usage in Cattle Barns. Sensors, 24(22), 7117. https://doi.org/10.3390/s24227117
Vancouver
Flessner M, König F, Guse C, Iwersen M, Klein-Jöbstl D. Evaluation of a Temperature/Humidity Data Logger for the Usage in Cattle Barns. Sensors. 2024;24(22):7117. doi:10.3390/s24227117
BibTeX
@article{Flessner2024,
author = {Flessner, Malina and König, Felix and Guse, Christian and Iwersen, Michael and Klein-Jöbstl, Daniela},
title = {Evaluation of a Temperature/Humidity Data Logger for the Usage in Cattle Barns},
journal = {Sensors},
year = {2024},
volume = {24},
number = {22},
pages = {7117},
doi = {10.3390/s24227117}
}
EUVIMED