Spatial coherence-based evaluation of cavitation activity extent from acoustic cavitation noise under a flextensional transducer with a spherical cavity for sonophoresis

T. Kuroyama, S. Yamamoto, N. Sugita, T. Shinshi, H. Ogasawara, K. Mori

Japanese Journal of Applied Physics · 15.06.2026 · 65 (11) · 11SP11

DOI: 10.35848/1347-4065/ae6b91 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Applied Physics, online erschienen am 04.06.2026. Verfasst von T. Kuroyama und 5 weiteren Autor:innen. Die Arbeit nennt 52 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The spatial extent of acoustic cavitation activity under a flextensional ultrasonic transducer with an acoustic cavity dedicated to safe sonophoresis is determined from acoustic cavitation noise. The transducer structure localizes a high-pressure amplitude region to the vicinity of the cavity apex. Acoustic cavitation noise is acquired using two laterally separated hydrophones aligned beneath the transducer, and the bubble distribution treated as an acoustic emission source is reconstructed using a van Cittert–Zernike theorem-based framework. The reconstructed one-dimensional projected distribution is compared with sonochemiluminescence (SCL) distribution. The results confirm that acoustic reconstruction yields the expected localized distribution near the cavity apex. In contrast, the SCL distribution indicates a broader pattern, suggesting a discrepancy between mechanical (acoustical) and chemical yields of bubbles.

Zitieren

APA

Kuroyama, T., Yamamoto, S., Sugita, N., Shinshi, T., Ogasawara, H., & Mori, K. (2026). Spatial coherence-based evaluation of cavitation activity extent from acoustic cavitation noise under a flextensional transducer with a spherical cavity for sonophoresis. Japanese Journal of Applied Physics, 65(11), 11SP11. https://doi.org/10.35848/1347-4065/ae6b91

Vancouver

Kuroyama T, Yamamoto S, Sugita N, Shinshi T, Ogasawara H, Mori K. Spatial coherence-based evaluation of cavitation activity extent from acoustic cavitation noise under a flextensional transducer with a spherical cavity for sonophoresis. Japanese Journal of Applied Physics. 2026;65(11):11SP11. doi:10.35848/1347-4065/ae6b91

BibTeX
@article{Kuroyama2026,
  author = {Kuroyama, T. and Yamamoto, S. and Sugita, N. and Shinshi, T. and Ogasawara, H. and Mori, K.},
  title = {Spatial coherence-based evaluation of cavitation activity extent from acoustic cavitation noise under a flextensional transducer with a spherical cavity for sonophoresis},
  journal = {Japanese Journal of Applied Physics},
  year = {2026},
  volume = {65},
  number = {11},
  pages = {11SP11},
  doi = {10.35848/1347-4065/ae6b91}
}
Kostenlos starten →