Diseño y aplicación de dispositivo para proyección radiográfica de la mortaja tibio-astragalina

FA Garcini-Munguia, R García-García, E Navarro-Martínez, S Zapien-Aguila, JL Rojas-Avilés

Acta Ortopédica Mexicana · 2024

DOI: 10.35366/115076 ↗

At a glance

Journal article in Acta Ortopédica Mexicana, 2024. Written by FA Garcini-Munguia and 4 co-authors. 13 references.

AstrattDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Introduction: ligamentous injuries of the distal tibiofibular syndesmosis resulting in its opening are common occurrences in traumatology; however, their diagnosis poses a challenge for orthopedic surgeons. The tibioastragaloid mortise radiograph view is the most commonly used method for diagnosing this type of injury, but its reliability is compromised due to variations in ankle positioning during the study, which often depend on the operator. Objective: to demonstrate that the designed device achieves a correct and consistent radiographic image of the distal tibiofibular syndesmosis in the mortise view. Material and methods: we present a prospective, longitudinal, observational study. We designed a polypropylene device that maintains the ankle at 90 degrees of dorsiflexion and 15 degrees of internal rotation. The device was used to take mortise view radiographs of healthy ankles, and corresponding measurements were taken to assess the syndesmosis. Results: we evaluated a total of 46 radiographs of healthy ankles, with a predominance of left ankles. The obtained measurements were as follows: anterior tibiofibular distance (ATFD) ranged from 3 to 6 mm, posterior tibiofibular distance (PTFD) ranged from 1 to 3 mm, tibiofibular clear space (TFCS) ranged from 2 to 3 mm, and a Merle D’Aubigne ratio of 2:1 was observed in all ankles. When comparing the measurements obtained with those established by Harper and Keller, no statistically significant difference was found (χ2 < 5). Conclusion: with the use of the designed device, we achieved a correct and consistent radiographic image of the mortise and the distal tibiofibular syndesmosis.

Cite

APA

Garcini-Munguia, F., García-García, R., Navarro-Martínez, E., Zapien-Aguila, S., & Rojas-Avilés, J. (2024). Diseño y aplicación de dispositivo para proyección radiográfica de la mortaja tibio-astragalina. Acta Ortopédica Mexicana. https://doi.org/10.35366/115076

Vancouver

Garcini-Munguia F, García-García R, Navarro-Martínez E, Zapien-Aguila S, Rojas-Avilés J. Diseño y aplicación de dispositivo para proyección radiográfica de la mortaja tibio-astragalina. Acta Ortopédica Mexicana. 2024. doi:10.35366/115076

BibTeX
@article{GarciniMunguia2024,
  author = {Garcini-Munguia, FA and García-García, R and Navarro-Martínez, E and Zapien-Aguila, S and Rojas-Avilés, JL},
  title = {Diseño y aplicación de dispositivo para proyección radiográfica de la mortaja tibio-astragalina},
  journal = {Acta Ortopédica Mexicana},
  year = {2024},
  doi = {10.35366/115076}
}
Start for free →