EUVIMEDOtkrijte EUVIMED
Crossref

Estudio experimental cadavérico para valorar el sistema de protección y guía de osteotomía (BARU) en cirugías de hallux valgus con técnica de Reverdin-Isham

J Del Castillo, M Russi, P Filomeno, JE Kenny-Pujadas, JA Cabrera-Frola, A Fischer, JC Bongiovanni, J Amaya

Acta Ortopédica Mexicana · 2021

DOI: 10.35366/101855 ↗

At a glance

Journal article in Acta Ortopédica Mexicana, 2021. Written by J Del Castillo and 7 co-authors. 14 references.

SažetakBibliografski podaciCiteRelated studies

Abstract (original language)

Introduction

Hallux valgus is a high frequency disorder, affecting the first ray. Operative correction techniques have grown popularity lately. One of them is the Reverdin-Isham technique (first metatarsal medial incomplete osteotomy). Recently, a protection and osteotomy cutting guide has been developed: the BARU system.

Objective

To test the usefulness of the BARU system as a protective factor for soft structures adjacent to the surgical site and guidance for osteotomy. Material and methods: Experimental cadaveric study. Six cadaveric feet (two fresh-frozen and four in formaldehyde solution), unapproached. Feet were numbered and intervened with RI technique, three of them with BARU system and three without it. Afterwards, dissection by two dissectors who did not know whether the BARU system had been used or not, establishing a single-blinded model. 13 structures were evaluated in each foot. Data was recovered into Microsoft Office Excel and processed with SPSS. χ2 test (significative if p value < 0.05) and relative risk were calculated.

Results

Approach using BARU system was satisfactory, with usual-size operation-ports. BARU system colocation was simple and radiological control showed adequate spatial location. The device contributed as reference for cutting direction and depth. 65 out of the 78 searched structures were found (83.3%). Six injuries were found among the assessed structures: plantar medial nerve (one injury), plantar medial artery (one injury), flexor brevis muscle (three injuries), abductor muscle (one injury). Five of these injuries occurred in non-utilizing BARU system feet.

Conclusion

Promising results in terms of protection of nearby structures, cutting guide, and ease of intervention. Avoids X-rays exposure. Not significant statistical calculations, the sample should be enlarged.

Cite

APA

Castillo, J. D., Russi, M., Filomeno, P., Kenny-Pujadas, J., Cabrera-Frola, J., Fischer, A., Bongiovanni, J., & Amaya, J. (2021). Estudio experimental cadavérico para valorar el sistema de protección y guía de osteotomía (BARU) en cirugías de hallux valgus con técnica de Reverdin-Isham. Acta Ortopédica Mexicana. https://doi.org/10.35366/101855

Vancouver

Castillo JD, Russi M, Filomeno P, Kenny-Pujadas J, Cabrera-Frola J, Fischer A, et al. Estudio experimental cadavérico para valorar el sistema de protección y guía de osteotomía (BARU) en cirugías de hallux valgus con técnica de Reverdin-Isham. Acta Ortopédica Mexicana. 2021. doi:10.35366/101855

BibTeX
@article{Castillo2021,
  author = {Castillo, J Del and Russi, M and Filomeno, P and Kenny-Pujadas, JE and Cabrera-Frola, JA and Fischer, A and Bongiovanni, JC and Amaya, J},
  title = {Estudio experimental cadavérico para valorar el sistema de protección y guía de osteotomía (BARU) en cirugías de hallux valgus con técnica de Reverdin-Isham},
  journal = {Acta Ortopédica Mexicana},
  year = {2021},
  doi = {10.35366/101855}
}
Start for free →