EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Tris(1,3-dichloropropyl) phosphate – Determination of bis(1,3-dichloropropyl) phosphate in urine by LC-APCI-ESI-MS/MS

Petra Krystek, Henry Beeltje, Marc Machiel George Houtzager, Eric Martin van den Hoeven, Laura Kuhlmann, Elisabeth Eckert, Thomas Göen, Andrea Hartwig, MAK Commission

The MAK Collection for Occupational Health and Safety · 2024 · 9 (4) · Doc097-Doc097

DOI: 10.34865/bi72236e9_4or ↗

Kurz gefasst

Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2024. Verfasst von Petra Krystek und 8 weiteren Autor:innen. Beteiligte Einrichtung: TNO - Location Utrecht. Environmental Monitoring. Sensing and Analysis P.O. Box 80015 NL-3508 TA Utrecht The Netherlands. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The working group “Analyses in Biological Materials” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified this biomonitoring method for the determination of urinary concentrations of bis(1,3‑dichloropropyl) phosphate (BDCPP), which is the major metabolite of tris(1,3‑dichloropropyl) phosphate (TDCPP). TDCPP is one of the most commonly used organophosphate flame retardants in cars, residential furniture, and products containing polyurethane foam, and has been detected in dust from private houses, office buildings, and car interiors, suggesting that a majority of the general population is exposed to TDCPP. The aim of this work was to establish a reliable, selective, and sensitive method for the detection of BDCPP in urine. The urine samples are spiked with the internal standard d10‑BDCPP and slightly acidified. Cleanup by mixed-mode anion-exchange solid-phase extraction is applied, and BDCPP is detected by liquid chromatography with simultaneous atmospheric pressure chemical ionisation and electrospray ionisation-tandem mass spectrometry. Calibration is carried out in ultra-pure water ∶ MeOH (4 ∶ 1, v/v). Good precision data with standard deviations below 7%, as well as good accuracy data with mean relative recoveries in the range of 93.6–101%, show that the method provides reliable and accurate analytical results. The method is both selective and sensitive, and the limit of quantitation of 0.2 ng BDCPP/l urine is sufficient to determine occupational exposure as well as higher background exposure levels to TDCPP in the general population.

Schlagwörter

Stichwörter der Autor:innen

BDCPPLC-APCI-ESI-MS/MSTDCPPbiomonitoringflame retardanturine

Autor:innen und Institutionen

  • TNO - Location Utrecht. Environmental Monitoring. Sensing and Analysis P.O. Box 80015 NL-3508 TA Utrecht The Netherlands.
  • Friedrich-Alexander-Universität Erlangen-Nürnberg. Institute and Outpatient Clinic of Occupational, Social, and Environmental Medicine Henkestraße 9-11 91054 Erlangen Germany.
  • Institute of Applied Biosciences. Department of Food Chemistry and Toxicology. Karlsruhe Institute of Technology (KIT) Adenauerring 20a, Building 50.41 76131 Karlsruhe Germany.

Zitieren

APA

Krystek, P., Beeltje, H., Houtzager, M. M. G., van den Hoeven, E. M., Kuhlmann, L., Eckert, E., Göen, T., Hartwig, A., & MAK Commission (2024). Tris(1,3-dichloropropyl) phosphate – Determination of bis(1,3-dichloropropyl) phosphate in urine by LC-APCI-ESI-MS/MS. The MAK Collection for Occupational Health and Safety, 9(4), Doc097-Doc097. https://doi.org/10.34865/bi72236e9_4or

Vancouver

Krystek P, Beeltje H, Houtzager MMG, van den Hoeven EM, Kuhlmann L, Eckert E, et al. Tris(1,3-dichloropropyl) phosphate – Determination of bis(1,3-dichloropropyl) phosphate in urine by LC-APCI-ESI-MS/MS. The MAK Collection for Occupational Health and Safety. 2024;9(4):Doc097-Doc097. doi:10.34865/bi72236e9_4or

BibTeX
@article{Krystek2024,
  author = {Krystek, Petra and Beeltje, Henry and Houtzager, Marc Machiel George and van den Hoeven, Eric Martin and Kuhlmann, Laura and Eckert, Elisabeth and Göen, Thomas and Hartwig, Andrea and MAK Commission, MAK Commission},
  title = {Tris(1,3-dichloropropyl) phosphate – Determination of bis(1,3-dichloropropyl) phosphate in urine by LC-APCI-ESI-MS/MS},
  journal = {The MAK Collection for Occupational Health and Safety},
  year = {2024},
  volume = {9},
  number = {4},
  pages = {Doc097--Doc097},
  doi = {10.34865/bi72236e9_4or}
}
Kostenlos starten →