Mycotoxins – Determination of deoxynivalenol and deepoxydeoxynivalenol in urine by LC-MS/MS
The MAK Collection for Occupational Health and Safety · 2025 · 10 (2) · Doc046-Doc046
DOI: 10.34865/bi5148110e10_2or ↗Kurz gefasst
Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2025. Verfasst von Marion Berger und 6 weiteren Autor:innen. Beteiligte Einrichtung: Federal Institute for Occupational Safety and Health (BAuA). Division 4 - Hazardous Substances and Biological Agents. Unit 4.2 - Health Surveillance.…. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The working group “Analyses in Biological Materials” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented biomonitoring method. The aim of this method is the selective and sensitive quantitation of deoxynivalenol (DON; free DON plus glucuronides not otherwise specified) and its metabolite deepoxydeoxynivalenol (DOM‑1) in urine. After enzymatic hydrolysis of the urine sample and purification of the analytes on an immunoaffinity column, followed by preconcentration of the eluates under a stream of nitrogen, determination is carried out by high-performance liquid chromatography-tandem mass spectrometry (LC‑MS/MS). Calibration is performed with comparative standards prepared in urine and treated analogously to the samples to be analysed. DON is quantified using an internal standard (ISTD; 13C15‑DON), whereas DOM‑1 is quantified without the use of an ISTD. Good precision data with standard deviations below 9% for DON and below 6% for DOM‑1, as well as good accuracy data with mean relative recoveries in the range of 93–114% for DON and 97–103% for DOM‑1, show that the method provides reliable and accurate analytical results. The method is both selective and sensitive, and has a limit of quantitation of 0.179 μg/l for DON and of 0.26 μg/l for DOM‑1. Due to rapid renal excretion, the method is primarily suitable for analysing acute exposure which occurred only hours prior to sampling.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Federal Institute for Occupational Safety and Health (BAuA). Division 4 - Hazardous Substances and Biological Agents. Unit 4.2 - Health Surveillance. Biological Monitoring Nöldnerstraße 40/42 10317 Berlin Germany.
- German Federal Institute for Risk Assessment. Unit 54 - Food Safety Department Max-Dohrn-Straße 8-10 10589 Berlin Germany.
- Friedrich-Alexander-Universität Erlangen-Nürnberg. Institute and Outpatient Clinic of Occupational, Social, and Environmental Medicine Henkestraße 9-11 91054 Erlangen Germany.
- Institute of Applied Biosciences. Department of Food Chemistry and Toxicology. Karlsruhe Institute of Technology (KIT) Adenauerring 20a, Building 50.41 76131 Karlsruhe Germany.
Zitieren
APA
Berger, M., Marske, L., Monien, B., Siodlaczek, S., Göen, T., Hartwig, A., & MAK Commission (2025). Mycotoxins – Determination of deoxynivalenol and deepoxydeoxynivalenol in urine by LC-MS/MS. The MAK Collection for Occupational Health and Safety, 10(2), Doc046-Doc046. https://doi.org/10.34865/bi5148110e10_2or
Vancouver
Berger M, Marske L, Monien B, Siodlaczek S, Göen T, Hartwig A, et al. Mycotoxins – Determination of deoxynivalenol and deepoxydeoxynivalenol in urine by LC-MS/MS. The MAK Collection for Occupational Health and Safety. 2025;10(2):Doc046-Doc046. doi:10.34865/bi5148110e10_2or
BibTeX
@article{Berger2025,
author = {Berger, Marion and Marske, Lennart and Monien, Bernhard and Siodlaczek, Solveigh and Göen, Thomas and Hartwig, Andrea and MAK Commission, MAK Commission},
title = {Mycotoxins – Determination of deoxynivalenol and deepoxydeoxynivalenol in urine by LC-MS/MS},
journal = {The MAK Collection for Occupational Health and Safety},
year = {2025},
volume = {10},
number = {2},
pages = {Doc046--Doc046},
doi = {10.34865/bi5148110e10_2or}
}
EUVIMED