EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Germanium – Determination of germanium and its non-volatile inorganic compounds in workplace air using inductively coupled plasma mass spectrometry (ICP-MS)

Pitzke, Katrin, Wippich, Cornelia, Woznica, Anita, Hebisch, Ralph, Brock, Thomas Helmut, Hartwig, Andrea und 1 weitere

The MAK Collection for Occupational Health and Safety · 2024 · 9 (2)

DOI: 10.34865/am744056e9_2or ↗

Kurz gefasst

Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2024. Verfasst von Pitzke und 12 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The working group “Air Analyses” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented analytical method. This analytical method is a validated measurement procedure for the determination of germanium [7440-56-4] and its non-volatile compounds in workplace air in a concentration range of one tenth up to twice of the currently valid Occupational Exposure Limit Value (OELV) in Germany of 0.85 mg/m3 as germanium in the inhalable particle fraction. For sampling, a defined volume of air is drawn through a membrane filter (nitrocellulose). The flow rate is 10 l/min and sampling duration is 2 hours. Germanium is digested with a mixture of hydrofluoric and nitric acid in a microwave-assisted pressure digestion. The samples are subsequently analysed using mass spectrometry with inductively coupled plasma (ICP-MS). The quantitative determination is based on a calibration function. The limit of quantification is 0.004 µg/m3 for an air sample volume of 1200 l and 20 ml digestion volume. The mean recovery is 97.2% for germanium and 97.9% for germanium dioxide. The expanded uncertainty for the validation range of 0.085 to 1.7 mg/m3 is 35.7 to 24.4%.

Schlagwörter

LuftanalysenAnalysenmethodeArbeitsplatzmessungGefahrstoffeinatembare PartikelMembranfilterMikrowellengestützter DruckaufschlussBestimmungsgrenzeMessbereichProbenahme

Zitieren

APA

Pitzke, Katrin, Wippich, Cornelia, Woznica, Anita, Hebisch, Ralph, Brock, Helmut, T., Hartwig, Andrea, & Commission, M. (2024). Germanium – Determination of germanium and its non-volatile inorganic compounds in workplace air using inductively coupled plasma mass spectrometry (ICP-MS). The MAK Collection for Occupational Health and Safety, 9(2). https://doi.org/10.34865/am744056e9_2or

Vancouver

Pitzke, Katrin, Wippich, Cornelia, Woznica, Anita, et al. Germanium – Determination of germanium and its non-volatile inorganic compounds in workplace air using inductively coupled plasma mass spectrometry (ICP-MS). The MAK Collection for Occupational Health and Safety. 2024;9(2). doi:10.34865/am744056e9_2or

BibTeX
@article{Pitzke2024,
  author = {Pitzke and Katrin and Wippich and Cornelia and Woznica and Anita and Hebisch and Ralph and Brock and Helmut, Thomas and Hartwig and Andrea and Commission, MAK},
  title = {Germanium – Determination of germanium and its non-volatile inorganic compounds in workplace air using inductively coupled plasma mass spectrometry (ICP-MS)},
  journal = {The MAK Collection for Occupational Health and Safety},
  year = {2024},
  volume = {9},
  number = {2},
  doi = {10.34865/am744056e9_2or}
}
Kostenlos starten →