Kurz gefasst

Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2025. Verfasst von Cornelia Wippich und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Occupational Safety and Health of the DGUV (IFA). German Social Accident Insurance (DGUV) Alte Heerstraße 111 53757 Sankt Augustin Germ…. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The working group “Air Analyses” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented analytical method. This analytical method is a validated measurement procedure for the determination of gadolinium [7440-54-2] and its compounds in workplace air in a concentration range of one tenth up to twice of the general dust limit value for the respirable dust fraction in Germany of 1.25 mg/m3. For sampling, a defined volume of air is drawn through a membrane filter (cellulose nitrate). The flow rate is set to 10 l/min and sampling duration is 2 hours. Gadolinium is extracted with a mixture of hydrochloric and nitric acid or just nitric acid, depending on the digesting method – open hot-block or microwave-assisted pressure digestion. The samples are subsequently analysed using mass spectrometry with inductively coupled plasma (ICP-MS). The quantitative determination is based on a calibration function. The limit of quantification is 0.002 µg/m3 (open hot-block digestion) and 0.001 µg/m3 (microwave-assisted pressure digestion), respectively, based on an air sample volume of 1200 l and 20 ml digestion volume. The mean recovery is 95.1% (open hot-block digestion) and 94.7% (microwave-assisted pressure digestion), respectively. The expanded uncertainty for the validation range of 0.167 to 2.5 mg/m3 is 23.5 to 25.0%.

Schlagwörter

Stichwörter der Autor:innen

ICP-MSacid digestionair analysesanalytical methodgadoliniumhazardous substancemass spectrometry with inductively coupled plasmamembrane filterworkplace measurement

Autor:innen und Institutionen

  • Institute for Occupational Safety and Health of the DGUV (IFA). German Social Accident Insurance (DGUV) Alte Heerstraße 111 53757 Sankt Augustin Germany.
  • Friedrich-Alexander-Universität Erlangen-Nürnberg. Institute and Outpatient Clinic of Occupational, Social, and Environmental Medicine Henkestraße 9-11 91054 Erlangen Germany.
  • Federal Institute for Occupational Safety and Health (BAuA) Friedrich-Henkel-Weg 1-25 44139 Dortmund Germany.
  • German Social Accident Insurance, Institution for the raw materials and chemical industry, Prevention - Department of Hazardous Substances, Biological Agents and Analytical Chemistry Kurfürsten-Anlage 62 69115 Heidelber…
  • Institute of Applied Biosciences. Department of Food Chemistry and Toxicology. Karlsruhe Institute of Technology (KIT) Adenauerring 20a, Building 50.41 76131 Karlsruhe Germany.

Zitieren

APA

Wippich, C., Pitzke, K., Göen, T., Hebisch, R., Lewin-Kretzschmar, U., Hartwig, A., & MAK Commission https://www.dfg.de/de/ueber-uns/gremien/senat/arbeitsstoffe/mitglieder (2025). Gadolinium – Determination of gadolinium and its compounds in workplace air using inductively coupled plasma mass spectrometry (ICP-MS). The MAK Collection for Occupational Health and Safety, 10(1), Doc019-Doc019. https://doi.org/10.34865/am744054e10_1or

Vancouver

Wippich C, Pitzke K, Göen T, Hebisch R, Lewin-Kretzschmar U, Hartwig A, et al. Gadolinium – Determination of gadolinium and its compounds in workplace air using inductively coupled plasma mass spectrometry (ICP-MS). The MAK Collection for Occupational Health and Safety. 2025;10(1):Doc019-Doc019. doi:10.34865/am744054e10_1or

BibTeX
@article{Wippich2025,
  author = {Wippich, Cornelia and Pitzke, Katrin and Göen, Thomas and Hebisch, Ralph and Lewin-Kretzschmar, Uta and Hartwig, Andrea and MAK Commission https://www.dfg.de/de/ueber-uns/gremien/senat/arbeitsstoffe/mitglieder, MAK Commission https://www.dfg.de/de/ueber-uns/gremien/senat/arbeitsstoffe/mitglieder},
  title = {Gadolinium – Determination of gadolinium and its compounds in workplace air using inductively coupled plasma mass spectrometry (ICP-MS)},
  journal = {The MAK Collection for Occupational Health and Safety},
  year = {2025},
  volume = {10},
  number = {1},
  pages = {Doc019--Doc019},
  doi = {10.34865/am744054e10_1or}
}
Kostenlos starten →