Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis
Journal of Dental Research, Dental Clinics, Dental Prospects · 11.11.2020 · 14 (4) · 218-222
DOI: 10.34172/joddd.2020.039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dental Research, Dental Clinics, Dental Prospects, online erschienen am 11.11.2020. Verfasst von Ali Hafezeqoran und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Dental faculty, Tabriz University of Medical Sciences, Tabriz, Iran. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Designing a high strength all-ceramic fixed partial denture with favorable esthetics can be challenging for clinicians; this study aimed to evaluate the effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prostheses.
Methods
Two groups of twenty 3-unit monolithic zirconia (Sirona inCoris TZI, Sirona Dental Systems GmbH) bridges, extending from the mandibular first premolar to the first molar with different connector sizes (9 mm2 and 12 mm2 ), were divided into two subgroups with different connector designs (round and sharp). The specimens were subjected to the three-point bending test to obtain the fracture-bearing load. The results were reported using descriptive statistics (mean ± standard deviation). Mann-Whitney U test was used to compare the fracture load in two types of designs for each connector size and two connector size types for each connector design. The significance level was considered at P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, Dental faculty, Tabriz University of Medical Sciences, Tabriz, Iran.
ORCID-Profile: Ali Hafezeqoran, Yasser Hemmati, Ayshin Akbarzadeh
Zitieren
APA
Hafezeqoran, A., Koodaryan, R., Hemmati, Y., & Akbarzadeh, A. (2020). Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis. Journal of Dental Research, Dental Clinics, Dental Prospects, 14(4), 218-222. https://doi.org/10.34172/joddd.2020.039
Vancouver
Hafezeqoran A, Koodaryan R, Hemmati Y, Akbarzadeh A. Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis. Journal of Dental Research, Dental Clinics, Dental Prospects. 2020;14(4):218-222. doi:10.34172/joddd.2020.039
BibTeX
@article{Hafezeqoran2020,
author = {Hafezeqoran, Ali and Koodaryan, Roodabeh and Hemmati, Yasser and Akbarzadeh, Ayshin},
title = {Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis},
journal = {Journal of Dental Research, Dental Clinics, Dental Prospects},
year = {2020},
volume = {14},
number = {4},
pages = {218--222},
doi = {10.34172/joddd.2020.039}
}