EUVIMEDEUVIMED entdecken
Crossref

Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks

Mazen A Attia, Tamer E Shokry

The Journal of Prosthetic Dentistry · 2023-08 · 130 (2) · 242-249

DOI: 10.1016/j.prosdent.2021.09.027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2023-08. Verfasst von Mazen A Attia und 1 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt. Electronic address: mazen.ahme…. Hauptthemen laut MEDLINE: Dental Materials, Yttrium. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 51 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The new strength-gradient zirconia composed of 3-mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) and 5-mol% yttria-stabilized tetragonal zirconia polycrystal (5Y-TZP) has been claimed to have superior mechanical properties. However, data on the fracture resistance of 3-unit gradient 5Y-TZP and 3Y-TZP fixed partial denture frameworks are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of dynamic loading on the fracture resistance of gradient zirconia fixed partial denture frameworks. MATERIAL AND METHODS: Two standardized stainless-steel master dies were designed to simulate a mandibular left second premolar and second molar prepared to receive zirconia frameworks. The frameworks were designed with a 0.6-mm uniform wall thickness. The mesiodistal width of the connectors was 3 ±0.02 mm, and the occlusogingival height was 3 ±0.02 mm. Forty zirconia frameworks were fabricated and divided into 2 groups according to the tested materials (n=20): 3Y-TZP and gradient 5Y-TZP and 3Y-TZP. The frameworks were cemented onto their corresponding dies with a conventional glass ionomer cement. Half of the cemented frameworks in each group underwent 600 000 cycles of dynamic loading in a mastication simulator (n=10). The other half was fractured without dynamic loading (n=10). Fracture resistance measurements (N) for each framework were recorded by using a universal testing machine at a crosshead speed of 1 mm/min. A fractured framework from each group was examined by using a scanning electron microscope (SEM) at ×100 magnification. The data obtained were statistically analyzed by using 2-way ANOVA, the pairwise Tukey honestly significant difference (HSD), and simple main effect tests to detect the difference between group mean values (α=.05). RESULTS: The mean ±standard deviation of fracture load value before dynamic loading was 1919 ±193 N for the 3Y-TZP group and 908 ±99 N for the gradient 5Y-TZP and 3Y-TZP group. In addition, the mean fracture load value after dynamic loading was 1418 ±163 N for the 3Y-TZP group and 716 ±85 N for the gradient 5Y-TZP and 3Y-TZP group. The interaction between the effects of the zirconia material and dynamic loading on the fracture resistance was statistically significant (P=.002). The 3Y-TZP group had a statistically significant, higher fracture load mean value the gradient 5Y-TZP and 3Y-TZP group before and after dynamic loading (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental MaterialsYttriumMaterials TestingZirconiumDenture, Partial, FixedDental Stress AnalysisSurface Properties

Substanzen

Dental Materialsyttriazirconium oxideYttriumZirconium

Autor:innen und Institutionen

  • Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt. Electronic address: mazen.ahmed@dent.bsu.edu.eg.
  • Professor, Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt.

Zitieren

APA

Attia, M. A., & Shokry, T. E. (2023). Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks. The Journal of Prosthetic Dentistry, 130(2), 242-249. https://doi.org/10.1016/j.prosdent.2021.09.027

Vancouver

Attia MA, Shokry TE. Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks. The Journal of Prosthetic Dentistry. 2023;130(2):242-249. doi:10.1016/j.prosdent.2021.09.027

BibTeX
@article{Attia2023,
  author = {Attia, Mazen A and Shokry, Tamer E},
  title = {Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2023},
  volume = {130},
  number = {2},
  pages = {242--249},
  doi = {10.1016/j.prosdent.2021.09.027}
}
Kostenlos starten →