High-Stability and Fast Calibration-Free Temperature Measurement Based on Light-Induced Thermoelastic Spectroscopy
Ultrafast Science · 2025-01 · 5
DOI: 10.34133/ultrafastscience.0083 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrafast Science, online erschienen am 30.01.2025. Verfasst von Xiaonan Liu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Laboratory of Opto-Electronic Information Acquisition and Manipulation (Anhui University), Ministry of Education, Fundamental Research Funds for Central Universities of the Central South University.
Abstract (Originalsprache)
In this paper, a series of calibration-free temperature measurement methods based on light-induced thermoelastic spectroscopy (LITES) are proposed for the first time. These techniques utilize the steady-state and transient response characteristics of the quartz tuning fork (QTF), namely, the calibration-free LITES (CF-LITES) and calibration-free heterodyne LITES (CF-H-LITES) methods. Four methods, first harmonic (1 f ) difference signal to normalize the second harmonic (2 f ) fundamental signal (method I, 2 f fund /1 f diff ), 1 f overtone signal to normalize the 2 f fundamental signal (method II, 2 f fund /1 f over ), 1 f heterodyne difference signal to normalize the 2 f heterodyne fundamental signal (method III, 2 f - H fund /1 f-H diff ), and 1 f heterodyne overtone signal to normalize the 2 f heterodyne fundamental signal (method IV, 2 f-H fund /1 f-H over ), for simultaneously detecting 1 f and 2 f within the frequency response range of the QTF are proposed to achieve calibration-free measurement. A self-designed T-shaped QTF with low fundamental and overtone frequencies was used to increase the energy accumulation time, thereby enhancing the sensor signal level. A 3-stage tube furnace was adopted to verify the performance of these 4 methods. Experimental results showed that the errors for the 4 methods were less than 4%, with a standard deviation below 11 °C. Furthermore, the calibration-free method, which employs normalization of the 2 f signal with the 1 f signal, effectively mitigates the impact of laser beam jitter and power fluctuations on detection performance. A superior performance can be obtained by adopting the CF-H-LITES technique based on method IV. It not only has excellent detection performance but also reduces the measurement period to 4 s, which is about 5 times faster. This development shows substantial promise for expanding the application of the CF-LITES and CF-H-LITES techniques in harsh environments.
Förderung
- National Natural Science Foundation of China
- Key Laboratory of Opto-Electronic Information Acquisition and Manipulation (Anhui University), Ministry of Education
- Fundamental Research Funds for Central Universities of the Central South University
Zitieren
APA
Liu, X., Qiao, S., He, Y., & Ma, Y. (2025). High-Stability and Fast Calibration-Free Temperature Measurement Based on Light-Induced Thermoelastic Spectroscopy. Ultrafast Science, 5. https://doi.org/10.34133/ultrafastscience.0083
Vancouver
Liu X, Qiao S, He Y, Ma Y. High-Stability and Fast Calibration-Free Temperature Measurement Based on Light-Induced Thermoelastic Spectroscopy. Ultrafast Science. 2025;5. doi:10.34133/ultrafastscience.0083
BibTeX
@article{Liu2025,
author = {Liu, Xiaonan and Qiao, Shunda and He, Ying and Ma, Yufei},
title = {High-Stability and Fast Calibration-Free Temperature Measurement Based on Light-Induced Thermoelastic Spectroscopy},
journal = {Ultrafast Science},
year = {2025},
volume = {5},
doi = {10.34133/ultrafastscience.0083}
}
EUVIMED