EUVIMEDEUVIMED entdecken
Crossref

Lithium niobate tuning fork-enhanced photoacoustic spectroscopy and light-induced thermoelastic spectroscopy

Runqiu Wang, Guowei Han, Ying He, Shunda Qiao, Yufei Ma

Applied Physics Reviews · 01.12.2025 · 12 (4)

DOI: 10.1063/5.0277336 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Physics Reviews, online erschienen am 17.10.2025. Verfasst von Runqiu Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 55-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Open Subject of Hebei Key Laboratory of Advanced Laser Technology and Equipment, Heilongjiang Provincial Postdoctoral Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, the performance of two self-designed lithium niobate tuning forks (LiNTF), round-head and tapered LiNTFs, was systematically explored in lithium niobate-enhanced photoacoustic spectroscopy (LiNPAS) and light-induced thermoelastic spectroscopy (LITES) sensors. Finite element analysis results revealed that the stress and surface charge density of the LiNTFs were higher than those of the standard quartz tuning fork (QTF), owing to the high piezoelectric coefficient and electromechanical coupling coefficient of the LiNbO3. The sensing performance of the two LiNTFs was experimentally evaluated, and acetylene (C2H2) was used as the test gas for performance validation. In the C2H2–LiNPAS system, the 2f signal peak values of the round-head LiNTF and the tapered LiNTF were 3.47 times and 4.29 times higher than those of the standard QTF, respectively. When the average time reached 1000 s, the minimum detection limits (MDLs) of the sensor based on round-head LiNTF and the tapered LiNTF were 723 and 450 ppb, respectively. In the C2H2–LITES system, the 2f signal peak values of the round-head LiNTF and the tapered LiNTF were found to be 3.79 times and 5.13 times higher than that of the standard QTF. The MDLs of the LITES sensor based on the round-head LiNTF and the tapered LiNTF were determined to be 101 and 52 ppb, respectively.

Förderung

  • National Natural Science Foundation of China
  • Open Subject of Hebei Key Laboratory of Advanced Laser Technology and Equipment
  • Heilongjiang Provincial Postdoctoral Science Foundation
  • Natural Science Foundation of Heilongjiang Province
  • China Postdoctoral Science Foundation

Zitieren

APA

Wang, R., Han, G., He, Y., Qiao, S., & Ma, Y. (2025). Lithium niobate tuning fork-enhanced photoacoustic spectroscopy and light-induced thermoelastic spectroscopy. Applied Physics Reviews, 12(4). https://doi.org/10.1063/5.0277336

Vancouver

Wang R, Han G, He Y, Qiao S, Ma Y. Lithium niobate tuning fork-enhanced photoacoustic spectroscopy and light-induced thermoelastic spectroscopy. Applied Physics Reviews. 2025;12(4). doi:10.1063/5.0277336

BibTeX
@article{Wang2025,
  author = {Wang, Runqiu and Han, Guowei and He, Ying and Qiao, Shunda and Ma, Yufei},
  title = {Lithium niobate tuning fork-enhanced photoacoustic spectroscopy and light-induced thermoelastic spectroscopy},
  journal = {Applied Physics Reviews},
  year = {2025},
  volume = {12},
  number = {4},
  doi = {10.1063/5.0277336}
}
Kostenlos starten →