Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls

Saira Hussain, Hyeonu Heo, Yushun Zeng, Qifa Zhou, Yun Jing

Advanced Devices & Instrumentation · 2025-01 · 6

DOI: 10.34133/adi.0122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Devices & Instrumentation, online erschienen am 02.12.2025. Verfasst von Saira Hussain und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Program in Acoustics, The Pennsylvania State University, University Park, PA 16802, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcranial focused ultrasound (tFUS) is an emerging, noninvasive therapeutic approach for neurological conditions. However, its development is hindered by the skull, which serves as an important acoustic barrier. Although small animal models have been used extensively to study tFUS, the impact of the skull in these models remains poorly understood. To address this knowledge gap, this study experimentally examined the attenuation and defocusing effects of 2 ex vivo rat skulls on acoustic pressure fields at therapeutically relevant frequencies. Using 3 focused ultrasound transducers operating between 1 and 2.25 MHz, we evaluated the impact of rat skull characteristics, location of the focus, and frequency on ultrasound transmission loss, full width at half maximum (FWHM), and focal location. The results demonstrated that skull thickness and morphology substantially influence attenuation and defocusing. Higher frequencies, while offering sharper focus, also led to increased attenuation and defocusing. Furthermore, the position of the focus relative to the skull had a minimal effect on the outcomes. Overall, the presence of the rat skull resulted in a 50% to 88% reduction in focal intensity, a focal broadening of 1% to 53%, and a focal shift of −1.6 to 2.1 mm. These findings provide critical insights that can enhance the precision and efficacy of tFUS in preclinical applications using rats as a small animal model.

Autor:innen und Institutionen

  • Graduate Program in Acoustics, The Pennsylvania State University, University Park, PA 16802, USA.
  • Department of Mechanical Engineering, The University of Akron, Akron, OH 44325, USA.
  • Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Hussain, S., Heo, H., Zeng, Y., Zhou, Q., & Jing, Y. (2025). Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls. Advanced Devices & Instrumentation, 6. https://doi.org/10.34133/adi.0122

Vancouver

Hussain S, Heo H, Zeng Y, Zhou Q, Jing Y. Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls. Advanced Devices & Instrumentation. 2025;6. doi:10.34133/adi.0122

BibTeX
@article{Hussain2025,
  author = {Hussain, Saira and Heo, Hyeonu and Zeng, Yushun and Zhou, Qifa and Jing, Yun},
  title = {Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls},
  journal = {Advanced Devices & Instrumentation},
  year = {2025},
  volume = {6},
  doi = {10.34133/adi.0122}
}
Kostenlos starten →