Intravascular Ultrasound Is More Accurate Than Angiography in Arteriovenous Vascular Access Lesions
Kidney360 · 2026-08 · 7 (8) · 1741-1749
DOI: 10.34067/kid.0000001128 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Kidney360, online erschienen am 13.02.2026. Verfasst von James W Decker und 13 weiteren Autor:innen. Beteiligte Einrichtung: Renal Section, Department of Medicine, Boston University Chobanian and Avedesian School of Medicine, Boston, Massachusetts. Hauptthemen laut MEDLINE: Ultrasonography, Interventional, Arteriovenous Shunt, Surgical, Angiography, Graft Occlusion, Vascular. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Division of Diabetes, Endocrinology, and Metabolic Diseases, NIDDK NIH HHS, NHLBI NIH HHS.
Abstract (Originalsprache)
Key Points Angiography systematically underestimates lumen size in geometrically complex, highly vascular stenotic regions. Intravascular ultrasound maintains accurate, geometry-resilient measurements across stenotic lesions, closely matching computer-aided design ground truth even in lesions with >50% stenosis. Intravascular ultrasound is a more accurate tool for diagnosing and guiding intervention in arteriovenous vascular access dysfunction than angiography.
Background
Conventional angiography remains the standard diagnostic modality for arteriovenous (AV) access dysfunction in hemodialysis patients, but its geometric accuracy is limited. Intravascular ultrasound (IVUS) offers superior lesion detection, yet its absolute measurement accuracy remains uncertain. Using three-dimensional–printed vascular conduits as reference standards, we assessed the accuracy of IVUS versus angiography, hypothesizing that complex conduit geometry, quantified by Gaussian curvature, would exacerbate angiographic error.
Methods
Clinically relevant AV access geometries were modeled with computer-aided design (CAD) and fabricated using three-dimensional printing. Lumen diameters were measured by contrast angiography and IVUS and compared with CAD dimensions. Conduit geometry was characterized using finite element–based Gaussian curvature mapping. Paired Student t test, Tukey-Kramer correction for multiple testing, and linear mixed-effect modeling were performed to examine the influence of clustering of lesions within conduits.
Results
IVUS demonstrated significantly lower measurement error compared with angiography, especially in stenotic segments with >50% luminal narrowing, which persisted even after correction for multiple comparisons ( P < 0.05). These high-grade stenoses frequently coincided with regions of especially high positive or negative Gaussian curvature, reflecting complex conduit geometry. In such regions, angiography consistently underestimated lumen diameter, with error magnitude increasing in curved or tortuous lesions. IVUS measurements closely approximated CAD measurements, retaining accuracy even in severe stenoses. For mild stenoses (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Renal Section, Department of Medicine, Boston University Chobanian and Avedesian School of Medicine, Boston, Massachusetts.
- College of Engineering and Computing, University of South Carolina, Columbia, South Carolina.
- Interventional Radiology, Department of Radiology, Boston Medical Center, Boston, Massachusetts.
- Division of Vascular and Endovascular Surgery, Department of Surgery, Boston University Chobanian and Avedisian School of Medicine Boston Medical Center, Boston, Massachusetts.
- Boston Veterans Administration Healthcare System, Boston, Massachusetts.
- Renal-Electrolyte and Hypertension Division, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania.
ORCID-Profile: James W Decker, Dima BaniHani, Curtis HonShideler, Saran Lotfollahzadeh, David Jasen Wu Wong, Alik Farber, Laura M Dember, Suvranu Ganguli, Vijaya B Kolachalama, Tarek Shazly, Vipul C Chitalia
Förderung
- Division of Diabetes, Endocrinology, and Metabolic Diseases
- NIDDK NIH HHS
- NHLBI NIH HHS
- NHLBI Division of Intramural Research
- Boston University Chobanian and Avedisian School of Medicine
Zitieren
APA
Decker, J. W., BaniHani, D., HonShideler, C., Lotfollahzadeh, S., Wu Wong, D. J., Farber, A., Siracuse, J. J., Idrees, N., Dember, L. M., Bader, M., Ganguli, S., Kolachalama, V. B., Shazly, T., & Chitalia, V. C. (2026). Intravascular Ultrasound Is More Accurate Than Angiography in Arteriovenous Vascular Access Lesions. Kidney360, 7(8), 1741-1749. https://doi.org/10.34067/kid.0000001128
Vancouver
Decker JW, BaniHani D, HonShideler C, Lotfollahzadeh S, Wu Wong DJ, Farber A, et al. Intravascular Ultrasound Is More Accurate Than Angiography in Arteriovenous Vascular Access Lesions. Kidney360. 2026;7(8):1741-1749. doi:10.34067/kid.0000001128
BibTeX
@article{Decker2026,
author = {Decker, James W and BaniHani, Dima and HonShideler, Curtis and Lotfollahzadeh, Saran and Wu Wong, David Jasen and Farber, Alik and Siracuse, Jeffrey J and Idrees, Najia and Dember, Laura M and Bader, Mohammad and Ganguli, Suvranu and Kolachalama, Vijaya B and Shazly, Tarek and Chitalia, Vipul C},
title = {Intravascular Ultrasound Is More Accurate Than Angiography in Arteriovenous Vascular Access Lesions},
journal = {Kidney360},
year = {2026},
volume = {7},
number = {8},
pages = {1741--1749},
doi = {10.34067/kid.0000001128}
}
EUVIMED