Fachartikel in der Zeitschrift The Journal of Vascular Access, 2026. Verfasst von Jeevitha Brama Kumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Imaging, Faculty of Medicine, University Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Arteriovenous Shunt, Surgical, Renal Dialysis, Kidney Failure, Chronic, Subclavian Vein. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
Background
Central venous stenosis (CVS) is a clinically significant complication in patients who depend on long-term hemodialysis access. While digital subtraction angiography remains the diagnostic gold standard, it is invasive, costly, and exposes patients to contrast and radiation. This study examined the diagnostic value of a simple, non-invasive, radiation-free alternative—the ultrasound-guided “sniff test,” which assesses dynamic changes in subclavian vein diameter during a forceful sniff to screen for CVS. Despite its potential advantages, the diagnostic performance of this method has not been well established.
Method
A prospective study was conducted among 71 end-stage kidney disease (ESKD) patients scheduled for angiography. Each participant underwent a sniff test before the procedure. A reduction of more than 40% in subclavian vein diameter during sniffing was considered normal, indicating absence of stenosis. Angiographic findings were used as the reference standard. Clinical signs—specifically ipsilateral arm swelling and visible chest wall veins—were also evaluated for diagnostic utility.
Results
Angiography confirmed CVS in 32 patients (45.1%). The sniff test showed a strong association with stenosis (OR 20.9) and demonstrated solid diagnostic performance, with sensitivity of 84.4%, specificity of 79.5%, and an AUC of 0.82. A normal sniff test accurately excluded stenosis in the majority of patients without CVS (86.1%), whereas an abnormal result was predominantly seen among those with stenosis (77.1%). Arm swelling was also significantly associated with stenosis (OR 20.40) and showed good standalone diagnostic accuracy (sensitivity 75.0%, specificity 87.2%, AUC 0.81). Importantly, combining the sniff test with clinical assessment enhanced overall performance, achieving higher specificity (94.9%) and excellent discriminative ability (AUC 0.90).
Conclusion
In conclusion, the ultrasound sniff test is a promising, accessible, and accurate screening tool for CVS. Used alone or alongside clinical findings, it offers a practical method to identify patients who may benefit from confirmatory angiography—particularly valuable in resource-limited or radiation-averse settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Imaging, Faculty of Medicine, University Malaya, Kuala Lumpur, Malaysia.
- Institute for Clinical Research, National Institutes of Health Malaysia, Selangor, Malaysia.
- Department of Biomedical Imaging, University Malaya Medical Centre, Kuala Lumpur, Malaysia.
- Vascular Unit, Division of General Surgery, Department of Surgery, Faculty of Medicine, University Malaya, Kuala Lumpur, Malaysia.
- Division of Nephrology, Department of Medicine, Faculty of Medicine, University Malaya, Kuala Lumpur, Malaysia.
ORCID-Profile: Jeevitha Brama Kumar, Chye Chung Gan
Zitieren
APA
Brama Kumar, J., Swaminathan, P., Abas, M. Z., Chan, K. W., Ramli, A. R. H., & Gan, C. C. (2026). Central Vein stEnosis screeNing using Ultrasound guided Sniff test: A prospective diagnostic accuracy study (C-VENUS). The Journal of Vascular Access. https://doi.org/10.1177/11297298251414686
Vancouver
Brama Kumar J, Swaminathan P, Abas MZ, Chan KW, Ramli ARH, Gan CC. Central Vein stEnosis screeNing using Ultrasound guided Sniff test: A prospective diagnostic accuracy study (C-VENUS). The Journal of Vascular Access. 2026. doi:10.1177/11297298251414686
BibTeX
@article{BramaKumar2026,
author = {Brama Kumar, Jeevitha and Swaminathan, Prasath and Abas, Mohamad Zulfikrie and Chan, Kin Wong and Ramli, Ahmad Rafizi Hariz and Gan, Chye Chung},
title = {Central Vein stEnosis screeNing using Ultrasound guided Sniff test: A prospective diagnostic accuracy study (C-VENUS)},
journal = {The Journal of Vascular Access},
year = {2026},
doi = {10.1177/11297298251414686}
}
EUVIMED