Abstract (Originalsprache)
This paper presents an implementation of anindependent control of two-mechanically coupled PermanentMagnet Synchronous Motor (PMSM) fed by two Space VectorPulse Width Modulation (SVPWM) inverters in a separate modeand in the event of failure one leg of one inverter, fault tolerantmode. In a fault tolerant mode, the two motors can operate in anindependent control strategy from one inverter with five legs tomaintain a constant output coupled torque. The Field OrientedControl (FOC) strategy is used to control the stator current of thetwo motors through two separate paths. Such application is usedin the field of a coupled torque produced by multi-motors such asin subway applications. The whole system is simulated in Matlab/Simulink and the simulated results show a stable and robustnessa system which can maintain a constant developed torque with avelocity reaches to the rated under fault tolerant operation.
Zitieren
APA
Chasib, A., Abdulabbas, A., & Obed, A. (2016). Independent Control of Two-PMSM Fed by Two SVPWM Inverters with Fault Tolerant Operation. Basrah journal for engineering science. https://doi.org/10.33971/bjes.16.1.9
Vancouver
Chasib A, Abdulabbas A, Obed A. Independent Control of Two-PMSM Fed by Two SVPWM Inverters with Fault Tolerant Operation. Basrah journal for engineering science. 2016. doi:10.33971/bjes.16.1.9
BibTeX
@article{Chasib2016,
author = {Chasib, Ahmed and Abdulabbas, Ali and Obed, Adel},
title = {Independent Control of Two-PMSM Fed by Two SVPWM Inverters with Fault Tolerant Operation},