EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modified SVPWM-Based Fault-Tolerant Operation of a Seven-Phase PMSM Drive After Two-Phase Open-Circuit Fault

Kamel Saleh

Electronics · 06.11.2026 · 15 (21) · 5166

DOI: 10.3390/electronics15215166 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 06.11.2026. Verfasst von Kamel Saleh. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a novel fault-tolerant control (FTC) scheme for a seven-phase PMSM drive to enhance its performance when two phases experience an open-circuit failure at the same time. For example, phases “a” and “b” are considered first-neighbor phases, “a” and “c” are second-neighbor phases, and “a” and “d” are third-neighbor phases. This approach makes the drive system more reliable and helps to reduce torque and speed fluctuations. To maintain the Magnetomotive Force (MMF) and improve overall performance, the FTC method focuses on controlling the current’s magnitude and angle after the faults. The process starts by calculating the angles and magnitudes after the fault occurs in each scenario. Based on this new current distribution, a specific multidimensional SVPWM technique is designed for each fault case. When simulating the fault in phases “a” and “b”, the torque ripple decreased from 0.4 N·m to 0.1 N·m, and the speed ripple dropped from 10 rpm to 4 rpm after applying the new FTC. For the fault in phases “a” and “c”, the torque ripple went down from 0.25 N·m to 0.1 N·m, and the speed ripple reduced from 2 rpm to 0.3 rpm with the new FTC. In the case of a fault in phases “a” and “d”, the torque ripple was cut from 0.6 N·m to 0.2 N·m, and the speed ripple dropped from 5 rpm to 0.5 rpm after implementing the new FTC. Furthermore, the dynamic performance of the motor during faults and during changes in speed and load was just as good as when the motor was operating normally.

Zitieren

APA

Saleh, K. (2026). Modified SVPWM-Based Fault-Tolerant Operation of a Seven-Phase PMSM Drive After Two-Phase Open-Circuit Fault. Electronics, 15(21), 5166. https://doi.org/10.3390/electronics15215166

Vancouver

Saleh K. Modified SVPWM-Based Fault-Tolerant Operation of a Seven-Phase PMSM Drive After Two-Phase Open-Circuit Fault. Electronics. 2026;15(21):5166. doi:10.3390/electronics15215166

BibTeX
@article{Saleh2026,
  author = {Saleh, Kamel},
  title = {Modified SVPWM-Based Fault-Tolerant Operation of a Seven-Phase PMSM Drive After Two-Phase Open-Circuit Fault},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {21},
  pages = {5166},
  doi = {10.3390/electronics15215166}
}
Kostenlos starten →