A Novel Method for Anomaly Detection and Signal Calibration in Water Quality Monitoring of an Urban Water Supply System
Water · 26.04.2024 · 16 (9) · 1238
DOI: 10.3390/w16091238 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water, online erschienen am 26.04.2024. Verfasst von Jincheng Liu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ålesund municipality under a smart water and wastewater infrastructure project.
Abstract (Originalsprache)
Water quality monitoring plays a crucial role in urban water supply systems for the production of safe drinking water. However, the traditional approach to water monitoring in Norway relies on a periodic (weekly/biweekly/monthly) sampling and analysis of biological indicators, which fails to provide a timely response to changes in water quality. This research addresses this issue by proposing a data-driven solution that enhances the timeliness of water quality monitoring. Our research team applied a case study in Ålesund Kommune. A sensor platform has been deployed at Lake Brusdalsvatnet, the water source reservoir in Ålesund. This sensor module is capable of collecting data for 10 different physico-chemical indicators of water quality. Leveraging this sensor platform, we developed a CNN-AutoEncoder-SOM solution to automatically monitor, process, and evaluate water quality evolution in the lake. There are three components in this solution. The first one focuses on anomaly detection. We employed a recurrence map to encode the temporal dynamics and sensor correlations, which were then fed into a convolutional neural network (CNN) for classification. It is noted that this network achieved an impressive accuracy of up to 99.6%. Once an anomaly is detected, the data are calibrated in the second component using an AutoEncoder-based network. Since true values for calibration are unavailable, the results are evaluated through data analysis. With high-quality calibrated data in hand, we proceeded to cluster the data into different categories to establish water quality standards in the third component, where a self-organizing map (SOM) is applied. The results revealed that this solution demonstrated significant performance, with a silhouette score of 0.73, which illustrates a small in-cluster distance and large intra-cluster distance when the water was clustered into three levels. This system not only achieved the objective of developing a comprehensive solution for continuous water quality monitoring but also offers the potential for integration with other cyber–physical systems (CPSs) in urban water management.
Förderung
- Ålesund municipality under a smart water and wastewater infrastructure project
Zitieren
APA
Liu, J., Wu, D., Mohammed, H., & Seidu, R. (2024). A Novel Method for Anomaly Detection and Signal Calibration in Water Quality Monitoring of an Urban Water Supply System. Water, 16(9), 1238. https://doi.org/10.3390/w16091238
Vancouver
Liu J, Wu D, Mohammed H, Seidu R. A Novel Method for Anomaly Detection and Signal Calibration in Water Quality Monitoring of an Urban Water Supply System. Water. 2024;16(9):1238. doi:10.3390/w16091238
BibTeX
@article{Liu2024,
author = {Liu, Jincheng and Wu, Di and Mohammed, Hadi and Seidu, Razak},
title = {A Novel Method for Anomaly Detection and Signal Calibration in Water Quality Monitoring of an Urban Water Supply System},
journal = {Water},
year = {2024},
volume = {16},
number = {9},
pages = {1238},
doi = {10.3390/w16091238}
}
EUVIMED