Adeno-Associated Virus-like Particles’ Response to pH Changes as Revealed by nES-DMA
Viruses · 2023
DOI: 10.3390/v15061361 ↗Kurz gefasst
Fachartikel in der Zeitschrift Viruses, 2023. Verfasst von Samuele Zoratto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria. Hauptthemen laut MEDLINE: Dependovirus. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: TU Wien Bibliothek, Austrian Federal Ministry of Education, Science and Research.
Abstract (Originalsprache)
Gas-phase electrophoresis on a nano-Electrospray Gas-phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA) separates single-charged, native analytes according to the surface-dry particle size. A volatile electrolyte, often ammonium acetate, is a prerequisite for electrospraying. Over the years, nES GEMMA has demonstrated its unique capability to investigate (bio-)nanoparticle containing samples in respect to composition, analyte size, size distribution, and particle numbers. Virus-like particles (VLPs), being non-infectious vectors, are often employed for gene therapy applications. Focusing on adeno-associated virus 8 (AAV8) based VLPs, we investigated the response of these bionanoparticles to pH changes via nES GEMMA as ammonium acetate is known to exhibit these changes upon electrospraying. Indeed, slight yet significant differences in VLP diameters in relation to pH changes are found between empty and DNA-cargo-filled assemblies. Additionally, filled VLPs exhibit aggregation in dependence on the applied electrolyte’s pH, as corroborated by atomic force microscopy. In contrast, cryogenic transmission electron microscopy did not relate to changes in the overall particle size but in the substantial particle’s shape based on cargo conditions. Overall, we conclude that for VLP characterization, the pH of the applied electrolyte solution has to be closely monitored, as variations in pH might account for drastic changes in particles and VLP behavior. Likewise, extrapolation of VLP behavior from empty to filled particles has to be carried out with caution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria.
- Electron Microscopy Facility, Vienna BioCenter Core Facilities GmbH, A-1030 Vienna, Austria.
- Pharmaceutical Sciences, Baxalta Innovations GmbH (Part of Takeda), A-1221 Vienna, Austria.
ORCID-Profile: Samuele Zoratto, Michael Graninger, Martina Marchetti-Deschmann, Victor U Weiss
Förderung
- TU Wien Bibliothek
- Austrian Federal Ministry of Education, Science and Research
Zitieren
APA
Zoratto, S., Heuser, T., Friedbacher, G., Pletzenauer, R., Graninger, M., Marchetti-Deschmann, M., & Weiss, V. U. (2023). Adeno-Associated Virus-like Particles’ Response to pH Changes as Revealed by nES-DMA. Viruses. https://doi.org/10.3390/v15061361
Vancouver
Zoratto S, Heuser T, Friedbacher G, Pletzenauer R, Graninger M, Marchetti-Deschmann M, et al. Adeno-Associated Virus-like Particles’ Response to pH Changes as Revealed by nES-DMA. Viruses. 2023. doi:10.3390/v15061361
BibTeX
@article{Zoratto2023,
author = {Zoratto, Samuele and Heuser, Thomas and Friedbacher, Gernot and Pletzenauer, Robert and Graninger, Michael and Marchetti-Deschmann, Martina and Weiss, Victor U},
title = {Adeno-Associated Virus-like Particles’ Response to pH Changes as Revealed by nES-DMA},
journal = {Viruses},
year = {2023},
doi = {10.3390/v15061361}
}
EUVIMED