Empty and Full AAV Capsid Charge and Hydrophobicity Differences Measured with Single-Particle AFM
Langmuir · 25.04.2023 · 39 (16) · 5641-5648
DOI: 10.1021/acs.langmuir.2c02643 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, online erschienen am 11.04.2023. Verfasst von Caryn L Heldt und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Michigan Technological University, Houghton, Michigan 49931, United States. Hauptthemen laut MEDLINE: Capsid, Dependovirus. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIAID NIH HHS, National Institute of Allergy and Infectious Diseases, Pfizer.
Abstract (Originalsprache)
Adeno-associated virus (AAV) is showing promise as a therapy for diseases that contain a single-gene deletion or mutation. One major scale-up challenge is the removal of empty or non-gene of interest containing AAV capsids. Analytically, the empty capsids can be separated from full capsids using anion exchange chromatography. However, when scaled up to manufacturing, the minute changes in conductivity are difficult to consistently obtain. To better understand the differences in the empty and full AAV capsids, we have developed a single-particle atomic force microscopy (AFM) method to measure the differences in the charge and hydrophobicity of AAV capsids at the single-particle level. The atomic force microscope tip was functionalized with either a charged or a hydrophobic molecule, and the adhesion force between the functionalized atomic force microscope tip and the virus was measured. We measured a change in the charge and hydrophobicity between empty and full AAV2 and AAV8 capsids. The charge and hydrophobicity differences between AAV2 and AAV8 are related to the distribution of charge on the surface and not the total charge. We propose that the presence of nucleic acids inside the capsid causes minor but measurable changes in the capsid structure that lead to measurable surface changes in charge and hydrophobicity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemical Engineering, Michigan Technological University, Houghton, Michigan 49931, United States.
- Health Research Institute, Michigan Technological University, Houghton, Michigan 49931, United States.
- Gene Therapy Process Development, Bioprocess Research and Development, Biotherapeutics Pharmaceutical Sciences, Pfizer, Chesterfield, Missouri 63017, United States.
ORCID-Profile: Caryn L Heldt, Pratik U Joshi, Xue Mi
Förderung
- NIAID NIH HHS
- National Institute of Allergy and Infectious Diseases
- Pfizer
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
Zitieren
APA
Heldt, C. L., Areo, O., Joshi, P. U., Mi, X., Ivanova, Y., & Berrill, A. (2023). Empty and Full AAV Capsid Charge and Hydrophobicity Differences Measured with Single-Particle AFM. Langmuir, 39(16), 5641-5648. https://doi.org/10.1021/acs.langmuir.2c02643
Vancouver
Heldt CL, Areo O, Joshi PU, Mi X, Ivanova Y, Berrill A. Empty and Full AAV Capsid Charge and Hydrophobicity Differences Measured with Single-Particle AFM. Langmuir. 2023;39(16):5641-5648. doi:10.1021/acs.langmuir.2c02643
BibTeX
@article{Heldt2023,
author = {Heldt, Caryn L and Areo, Oluwatoyin and Joshi, Pratik U and Mi, Xue and Ivanova, Yulia and Berrill, Alex},
title = {Empty and Full AAV Capsid Charge and Hydrophobicity Differences Measured with Single-Particle AFM},
journal = {Langmuir},
year = {2023},
volume = {39},
number = {16},
pages = {5641--5648},
doi = {10.1021/acs.langmuir.2c02643}
}
EUVIMED