Safety Profile of Suction-Assisted RIRS: A Prospective Analysis of Intraoperative Anesthetic Events
Uro · 13.07.2026 · 6 (3) · 19
DOI: 10.3390/uro6030019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Uro, online erschienen am 13.07.2026. Verfasst von Paula María Sánchez Vicente und 5 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Retrograde intrarenal surgery (RIRS) is a well-established minimally invasive technique for the management of renal stones. However, intraoperative physiological and anesthetic events during the procedure remain poorly characterized, particularly in the context of newer technologies such as suction-assisted systems.
Objective
The objective of this study is to evaluate the occurrence of intraoperative anesthetic and physiological adverse events during suction-assisted RIRS and to assess its safety profile.
Methods
We conducted a prospective, single-center observational sub-analysis of the “Trifecta factors in ureteroscopy” project. A consecutive cohort of 30 patients undergoing RIRS with suction ureteral access sheaths (sUAS) between August 2025 and January 2026 was analyzed. Baseline demographics, stone characteristics, and intraoperative anesthetic parameters—including airway pressure, Bispectral Index (BIS), and hemodynamic events—were prospectively recorded. Primary endpoints included intraoperative fever, sustained tachycardia, blood pressure alterations, and anesthetic complications.
Results
The cohort had a mean age of 56.4 years with an equal gender distribution. Mean stone size was 12.9 mm, and mean operative time was 50.3 min. Intraoperative monitoring demonstrated stable anesthetic conditions, with a mean airway pressure of 16.3 cmH2O and a mean BIS of 42.6. No major anesthetic complications or significant blood pressure fluctuations were observed. Minor intraoperative events included fever in 10% of cases and sustained tachycardia in 6.7%. No cases of intraoperative anesthetic instability were recorded.
Conclusions
Within this descriptive cohort, suction-assisted RIRS under general anesthesia demonstrated a favorable safety profile with stable intraoperative parameters, though larger comparative studies are required to confirm these preliminary findings.
Zitieren
APA
Vicente, P. M. S., Szczesniewski, J. J., Suárez, C. R., Caballero, A. R., Gómez, M. F. L., & González, L. L. (2026). Safety Profile of Suction-Assisted RIRS: A Prospective Analysis of Intraoperative Anesthetic Events. Uro, 6(3), 19. https://doi.org/10.3390/uro6030019
Vancouver
Vicente PMS, Szczesniewski JJ, Suárez CR, Caballero AR, Gómez MFL, González LL. Safety Profile of Suction-Assisted RIRS: A Prospective Analysis of Intraoperative Anesthetic Events. Uro. 2026;6(3):19. doi:10.3390/uro6030019
BibTeX
@article{Vicente2026,
author = {Vicente, Paula María Sánchez and Szczesniewski, Juliusz Jan and Suárez, Cristina Rasines and Caballero, Alejandro Rodríguez and Gómez, María Fernanda Lorenzo and González, Luis Llanes},
title = {Safety Profile of Suction-Assisted RIRS: A Prospective Analysis of Intraoperative Anesthetic Events},
journal = {Uro},
year = {2026},
volume = {6},
number = {3},
pages = {19},
doi = {10.3390/uro6030019}
}
EUVIMED