EUVIMEDEUVIMED entdecken
MetaanalyseSystematische Übersicht

Diagnostic Performance and Safety Profile of Robotic-assisted Bronchoscopy: A Systematic Review and Meta-Analysis

Muhammad Sajawal Ali iD, Uzair Khan Ghori, Max Theodore Wayne iD, Eugene Shostak, Jose De Cardenas

Annals of the American Thoracic Society · 01.12.2023 · 20 (12) · 1801-1812

DOI: 10.1513/annalsats.202301-075oc ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Annals of the American Thoracic Society, online erschienen am 01.12.2023. Verfasst von Muhammad Sajawal Ali und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary and Critical Care Medicine. Hauptthemen laut MEDLINE: Lung Neoplasms, Robotic Surgical Procedures. Die Arbeit wurde bisher 92-mal zitiert (Crossref) und nennt 74 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Conventional electromagnetic navigation bronchoscopy and other guided bronchoscopic modalities have a very desirable safety profile, but their diagnostic yield is only 60–70% for pulmonary lesions. Recently, robotic-assisted bronchoscopy (RAB) platforms have been introduced to improve the diagnostic performance of bronchoscopic modalities.

Objectives

To determine the diagnostic performance and safety profile of RAB (using shape-sensing and electromagnetic navigation–based platforms) by performing a systematic review and meta-analysis.

Methods

The PubMed, Embase, and Google Scholar databases were searched to find studies that reported on the diagnostic performance and/or the safety profile of one of the RAB systems. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Meta-analysis was performed using MedCalc version 20.118. Pooled diagnostic yield was calculated using a Freeman-Tukey transformation. We planned to use a random-effects model if the I 2 index was >40%.

Results

Twenty-five studies were included: 20 including diagnostic and safety analyses and 5 including only safety analyses. The pooled diagnostic yield of RAB (20 studies, 1,779 lesions) was 84.3% (95% confidence interval, 81.1–87.2%). The I 2 index was 65.6%. On the basis of our subgroup analyses, the heterogeneity was likely driven by differences in study designs (prospective vs. retrospective) and procedural protocols (such as different RAB systems). Lesion size > 2 cm, the presence of a computed tomography bronchus sign, and concentric radial endobronchial ultrasound view were associated with a statistically significant increase in the odds of diagnosis with RAB. The overall rates of pneumothorax, need for tube thoracostomy, and significant hemorrhage were 2.3%, 1.2%, and 0.5%, respectively.

Conclusions

RAB systems have significantly increased the diagnostic yield of navigational bronchoscopy compared with conventional systems such as electromagnetic navigation bronchoscopy, but well-designed prospective studies are needed to better understand the impact of various factors, such as the use of three-dimensional imaging modalities, cryobiopsy, and specific ventilatory protocols, on the diagnostic yield of RAB.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsRobotic Surgical ProceduresHumansBronchoscopyProspective StudiesRetrospective Studies

Stichwörter der Autor:innen

electromagnetic navigation robotic-assisted bronchoscopylung nodulenavigational bronchoscopyrobotic bronchoscopyshape-sensing robotic-assisted bronchoscopy

Autor:innen und Institutionen

  • Division of Pulmonary and Critical Care Medicine.
  • Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, New York.
  • Division of Pulmonary, Critical Care and Sleep Medicine, Medical College of Wisconsin, Milwaukee, Wisconsin; and.
  • Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan.

ORCID-Profile: Muhammad Sajawal Ali, Max Theodore Wayne

Zitieren

APA

Ali, M. S., Ghori, U. K., Wayne, M. T., Shostak, E., & De Cardenas, J. (2023). Diagnostic Performance and Safety Profile of Robotic-assisted Bronchoscopy: A Systematic Review and Meta-Analysis. Annals of the American Thoracic Society, 20(12), 1801-1812. https://doi.org/10.1513/annalsats.202301-075oc

Vancouver

Ali MS, Ghori UK, Wayne MT, Shostak E, De Cardenas J. Diagnostic Performance and Safety Profile of Robotic-assisted Bronchoscopy: A Systematic Review and Meta-Analysis. Annals of the American Thoracic Society. 2023;20(12):1801-1812. doi:10.1513/annalsats.202301-075oc

BibTeX
@article{Ali2023,
  author = {Ali, Muhammad Sajawal and Ghori, Uzair Khan and Wayne, Max Theodore and Shostak, Eugene and De Cardenas, Jose},
  title = {Diagnostic Performance and Safety Profile of Robotic-assisted Bronchoscopy: A Systematic Review and Meta-Analysis},
  journal = {Annals of the American Thoracic Society},
  year = {2023},
  volume = {20},
  number = {12},
  pages = {1801--1812},
  doi = {10.1513/annalsats.202301-075oc}
}
Kostenlos starten →