Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation

Angela Peck, Rodney G Handy, Darrah K Sleeth, Camie Schaefer iD, Yue Zhang, Leon F Pahler, Joemy Ramsay, Scott C Collingwood

Toxics · 06.01.2023 · 11 (1) · 56

DOI: 10.3390/toxics11010056 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Toxics, online erschienen am 06.01.2023. Verfasst von Angela Peck und 7 weiteren Autor:innen. Beteiligte Einrichtung: Occupational and Environmental Health, Department of Family and Preventive Medicine, University of Utah, Salt Lake City, UT 84108, USA. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NIH HHS, National Institute for Occupational Safety and Health (NIOSH) Education and Research Center (ERC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing concern over air pollution has led to the development of low-cost sensors suitable for wide-scale deployment and use by citizen scientists. This project investigated the AirU low-cost particle sensor using two methods: (1) a comparison of pre- and post-deployment calibration equations for 24 devices following use in a field study, and (2) an in-home comparison between 3 AirUs and a reference instrument, the GRIMM 1.109. While differences (and therefore some sensor degradation) were found in the pre- and post-calibration equation comparison, absolute value changes were small and unlikely to affect the quality of results. Comparison tests found that while the AirU did tend to underestimate minimum and overestimate maximum concentrations of particulate matter, ~88% of results fell within ±1 μg/m3 of the GRIMM. While these tests confirm that low-cost sensors such as the AirU do experience some sensor degradation over multiple months of use, they remain a valuable tool for exposure assessment studies. Further work is needed to examine AirU performance in different environments for a comprehensive survey of capability, as well as to determine the source of sensor degradation.

Schlagwörter

Stichwörter der Autor:innen

citizen scienceexposure assessmentlow-cost sensorsparticulate mattersensor degradation

Autor:innen und Institutionen

  • Occupational and Environmental Health, Department of Family and Preventive Medicine, University of Utah, Salt Lake City, UT 84108, USA.
  • Department of Family and Preventive Medicine, University of Utah, Salt Lake City, UT 84108, USA.
  • Department of Internal Medicine, University of Utah, Salt Lake City, UT 84108, USA.
  • Department of Pediatrics, University of Utah, Salt Lake City, UT 84108, USA.

ORCID-Profile: Camie Schaefer

Förderung

  • NIBIB NIH HHS
  • NIH HHS
  • National Institute for Occupational Safety and Health (NIOSH) Education and Research Center (ERC)
  • National Institutes of Health ECHO
  • National Institute of Biomedical Imaging and Bioengineering PRISMS

Zitieren

APA

Peck, A., Handy, R. G., Sleeth, D. K., Schaefer, C., Zhang, Y., Pahler, L. F., Ramsay, J., & Collingwood, S. C. (2023). Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation. Toxics, 11(1), 56. https://doi.org/10.3390/toxics11010056

Vancouver

Peck A, Handy RG, Sleeth DK, Schaefer C, Zhang Y, Pahler LF, et al. Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation. Toxics. 2023;11(1):56. doi:10.3390/toxics11010056

BibTeX
@article{Peck2023,
  author = {Peck, Angela and Handy, Rodney G and Sleeth, Darrah K and Schaefer, Camie and Zhang, Yue and Pahler, Leon F and Ramsay, Joemy and Collingwood, Scott C},
  title = {Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation},
  journal = {Toxics},
  year = {2023},
  volume = {11},
  number = {1},
  pages = {56},
  doi = {10.3390/toxics11010056}
}
Kostenlos starten →