Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning

Fernando U Kay iD, Cynthia Lumby, Yuki Tanabe, Suhny Abbara, Prabhakar Rajiah

Tomography · 2023

DOI: 10.3390/tomography9040123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, 2023. Verfasst von Fernando U Kay und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Angiography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate if dual-energy CT (DECT) pulmonary angiography (CTPA) can detect anemia with the aid of machine learning.

Methods

Inclusion of 100 patients (mean age ± SD, 51.3 ± 14.8 years; male-to-female ratio, 42/58) who underwent DECT CTPA and hemoglobin (Hb) analysis within 24 h, including 50 cases with Hb below and 50 controls with Hb ≥ 12 g/dL. Blood pool attenuation was assessed on virtual noncontrast (VNC) images at eight locations. A classification model using extreme gradient-boosted trees was developed on a training set (n = 76) for differentiating cases from controls. The best model was evaluated in a separate test set (n = 24).

Results

Blood pool attenuation was significantly lower in cases than controls (p-values < 0.01), except in the right atrium (p = 0.06). The machine learning model had sensitivity, specificity, and accuracy of 83%, 92%, and 88%, respectively. Measurements at the descending aorta had the highest relative importance among all features; a threshold of 43 HU yielded sensitivity, specificity, and accuracy of 68%, 76%, and 72%, respectively.

Conclusion

VNC imaging and machine learning shows good diagnostic performance for detecting anemia on DECT CTPA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyAngiographyHumansFeasibility StudiesMachine Learning

Stichwörter der Autor:innen

anemiacomputed tomography angiographymachine learningpulmonary embolism

Autor:innen und Institutionen

  • Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA.
  • Veterans Affairs North Texas Health Care System, Dallas, TX 75216, USA.
  • Department of Radiology, Ehime University, Matsuyama 790-0825, Japan.
  • Department of Radiology, Mayo Clinic, Rochester, MN 55901, USA.

ORCID-Profile: Fernando U Kay

Zitieren

APA

Kay, F. U., Lumby, C., Tanabe, Y., Abbara, S., & Rajiah, P. (2023). Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning. Tomography. https://doi.org/10.3390/tomography9040123

Vancouver

Kay FU, Lumby C, Tanabe Y, Abbara S, Rajiah P. Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning. Tomography. 2023. doi:10.3390/tomography9040123

BibTeX
@article{Kay2023,
  author = {Kay, Fernando U and Lumby, Cynthia and Tanabe, Yuki and Abbara, Suhny and Rajiah, Prabhakar},
  title = {Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning},
  journal = {Tomography},
  year = {2023},
  doi = {10.3390/tomography9040123}
}
Kostenlos starten →