Comparing Radiation Dose of Cerebral Angiography Using Conventional and High kV Techniques: A Retrospective Study on Intracranial Aneurysm Patients and a Phantom Study
Tomography · 08.03.2023 · 9 (2) · 621-632
DOI: 10.3390/tomography9020050 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, online erschienen am 08.03.2023. Verfasst von Woranan Kirisattayakul und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand. Hauptthemen laut MEDLINE: Intracranial Aneurysm. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research and Graduate Studies, Khon Kaen University.
Abstract (Originalsprache)
Evaluation of patient radiation dose after the implementation of a high kV technique during a cerebral angiographic procedure is an important issue. This study aimed to determine and compare the patient radiation dose of intracranial aneurysm patients undergoing cerebral angiography using the conventional and high kV techniques in a retrospective study and a phantom study. A total of 122 cases (61 cases with conventional technique and 61 cases with high kV technique) of intracranial aneurysm patients, who underwent cerebral angiographic procedure and met the inclusion criteria, were recruited. The radiation dose and the angiographic exposure parameters were reviewed retrospectively. The radiation dose in the phantom study was conducted using nanoDotTM optically stimulating luminescence (OSLD), which were placed on the scalp of the head phantom, the back of the neck, and the phantom skin at the position of the eyes. The standard cerebral angiographic procedure using the conventional and high kV techniques was performed following the standard protocol. The results showed that the high kV technique significantly reduced patient radiation dose and phantom skin dose. This study confirms that the implementation of a high kV technique in routine cerebral angiography for aneurysm diagnosis provides an effective reduction in radiation dose. Further investigation of radiation dose in other interventional neuroradiology procedures, particularly embolization procedure, should be performed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand.
- Office of Atoms for Peace, Ministry of Higher Education, Science, Research and Innovation, Bangkok 10900, Thailand.
ORCID-Profile: Woranan Kirisattayakul, Thawatchai Prabsattroo
Förderung
- Research and Graduate Studies, Khon Kaen University
Zitieren
APA
Kirisattayakul, W., Pattum, P., Munkong, W., Prabsattroo, T., Khottapat, C., Chomkhunthod, T., & Pungkun, V. (2023). Comparing Radiation Dose of Cerebral Angiography Using Conventional and High kV Techniques: A Retrospective Study on Intracranial Aneurysm Patients and a Phantom Study. Tomography, 9(2), 621-632. https://doi.org/10.3390/tomography9020050
Vancouver
Kirisattayakul W, Pattum P, Munkong W, Prabsattroo T, Khottapat C, Chomkhunthod T, et al. Comparing Radiation Dose of Cerebral Angiography Using Conventional and High kV Techniques: A Retrospective Study on Intracranial Aneurysm Patients and a Phantom Study. Tomography. 2023;9(2):621-632. doi:10.3390/tomography9020050
BibTeX
@article{Kirisattayakul2023,
author = {Kirisattayakul, Woranan and Pattum, Panuwat and Munkong, Waranon and Prabsattroo, Thawatchai and Khottapat, Chonnatcha and Chomkhunthod, Tanyalak and Pungkun, Vithit},
title = {Comparing Radiation Dose of Cerebral Angiography Using Conventional and High kV Techniques: A Retrospective Study on Intracranial Aneurysm Patients and a Phantom Study},
journal = {Tomography},
year = {2023},
volume = {9},
number = {2},
pages = {621--632},
doi = {10.3390/tomography9020050}
}
EUVIMED