EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement

Jung Bin Lee, Hye Shin Ahn, Leehi Joo, Younghee Yim iD

Tomography · 2026

DOI: 10.3390/tomography12090121 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Tomography, 2026. Verfasst von Jung Bin Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Republic of Korea. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chung-Ang University Hospital, the Biomedical Research Institute, Chung-Ang University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the clinical viability of compressed sensing magnetization, we prepared a rapid acquisition gradient echo (CS-MPRAGE) for brain volume measurement by comparing its scan time and image quality with standard MPRAGE.

Methods

In this retrospective study, we analyzed a total of 40 morphologically normal MRIs from relatively young subjects (mean age 27.03 ± 5.02, range 19~40, F:M = 33:7) who underwent both CS-MPRAGE and standard MPRAGE. MRI was performed with a 3T MR scanner using a 64-channel head coil. Volumetric data analysis was conducted using commercial AI-powered quantification software. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNRgray matter/white matter) were measured and compared. Qualitative analysis based on overall image quality, deep gray matter delineation, artifacts, and gray–white matter differentiation was rated on a five-point visual scoring system. Statistical analyses included paired t-tests, intraclass correlation coefficients (ICCs) and Pearson correlation.

Results

CS-MPRAGE had a significantly shorter scan time than standard MPRAGE (1:46 vs. 5:20 min; p < 0.001). Whole-brain volume was similar (standard-MPRAGE, 1176.89 ± 105.36; CS-MPRAGE, 1181.14 ± 105.62 mL; r = 0.988; ICC, 0.9754–0.9931). Gray matter and regional lobe volumes were comparable, while the white matter volume was slightly larger with CS-MPRAGE. CNR of the gray–white matter was significantly higher with CS-MPRAGE (left, 30.45 ± 11.21 vs. 49.53 ± 32.71; right, 30.73 ± 11.97 vs. 46.89 ± 30.40; p = 0.0001) while SNR were similar across key brain regions.

Conclusions

CS-MPRAGE provides high-quality 3D images and reliable volume data with significantly reduced acquisition time and comparable image quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainHumansRetrospective StudiesAdultFemaleSignal-To-Noise RatioReproducibility of ResultsMaleYoung AdultOrgan SizeImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedImaging, Three-Dimensional

Stichwörter der Autor:innen

brain volume measurementcompressed sensingmagnetization-prepared rapid acquisition gradient echo

Autor:innen und Institutionen

  • Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Republic of Korea.
  • Biomedical Research Institute, Chung-Ang University Hospital, Seoul 06973, Republic of Korea.

ORCID-Profile: Younghee Yim

Förderung

  • Chung-Ang University Hospital
  • the Biomedical Research Institute, Chung-Ang University Hospital

Zitieren

APA

Lee, J. B., Ahn, H. S., Joo, L., & Yim, Y. (2026). Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement. Tomography. https://doi.org/10.3390/tomography12090121

Vancouver

Lee JB, Ahn HS, Joo L, Yim Y. Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement. Tomography. 2026. doi:10.3390/tomography12090121

BibTeX
@article{Lee2026,
  author = {Lee, Jung Bin and Ahn, Hye Shin and Joo, Leehi and Yim, Younghee},
  title = {Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement},
  journal = {Tomography},
  year = {2026},
  doi = {10.3390/tomography12090121}
}
Kostenlos starten →