Utility of Native T1 Mapping for the Evaluation of Myocardial Iron Overload in Patients with Thalassemia Major
Tomography · 14.04.2026 · 12 (4) · 58
DOI: 10.3390/tomography12040058 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, online erschienen am 14.04.2026. Verfasst von Antonio Matteo Amadu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department of Surgery, Medicine and Pharmacy, University of Sassari, Viale S. Pietro, 07100 Sassari, Italy. Hauptthemen laut MEDLINE: Iron Overload, beta-Thalassemia, Magnetic Resonance Imaging, Myocardium. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
This study aimed to assess the utility of native T1 mapping for the evaluation of myocardial iron overload in patients with Thalassemia Major. T1 was compared to T2*, which represents the gold standard for iron quantification in the heart and liver.
Methods
Consecutive patients with Thalassemia Major who performed cardiac MRI at the University Hospital of Sassari between 2022 and 2024 were prospectively included. All patients underwent a 1.5 T MRI with the same scanner (Philips Ingenia). T2* and native T1 mapping (MOLLI) sequences were performed in all patients on a mid-ventricular single 8 mm short-axis slice of the left ventricle. A region of interest was manually drawn in the septal wall. A T2* value < 20 ms was considered indicative of significant myocardial iron overload. A normal lower limit value of 990 ms was adopted for native T1 mapping.
Results
In total, 100 patients with Thalassemia Major were included (median age, 45 [range, 7–80] years; 55% were male). The median myocardial T2* value was 31.4 (range, 5.1–47) and median T1 was 941 ms (range, 557–1131). A total of 12 patients (12%) exhibited T2* values < 20 ms; the T1 values in these patients (median, 733.8 ms [range, 557–975]) were significantly lower compared to those with a T2* of 20 ms or greater (median, 961 ms [range, 820–1131]), p < 0.001. No patient with T2* < 20 ms had a T1 value greater than or equal to 990 ms. Among the 88 patients with T2* ≥ 20 ms, 56 (64%) had T1 < 990 ms (median, 939.2 ms [range, 820–986]). Using a T1 threshold of 990 ms, the sensitivity was 100%, but the specificity was only 36%. ROC analysis identified an optimal T1 value of 895.5 ms, corresponding to 92% sensitivity and 100% specificity.
Conclusions
Native T1 mapping is highly sensitive for detecting myocardial iron overload in Thalassemia Major, but the standard 990 ms threshold generates many false-positive results. In our cohort, adopting an ROC-optimized threshold of 895.5 ms markedly improved specificity while preserving excellent sensitivity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology Department of Surgery, Medicine and Pharmacy, University of Sassari, Viale S. Pietro, 07100 Sassari, Italy.
- Department of Translational Research, Academic Radiology, University of Pisa, 56124 Pisa, Italy.
ORCID-Profile: Alberto Dessì, Leandra Piscopo, Emma Solinas, Davide Turilli, Mariano Scaglione
Zitieren
APA
Amadu, A. M., Contena, A., Dessì, A., Piscopo, L., Solinas, E., Turilli, D., Fanni, S. C., Scaglione, M., & Masala, S. (2026). Utility of Native T1 Mapping for the Evaluation of Myocardial Iron Overload in Patients with Thalassemia Major. Tomography, 12(4), 58. https://doi.org/10.3390/tomography12040058
Vancouver
Amadu AM, Contena A, Dessì A, Piscopo L, Solinas E, Turilli D, et al. Utility of Native T1 Mapping for the Evaluation of Myocardial Iron Overload in Patients with Thalassemia Major. Tomography. 2026;12(4):58. doi:10.3390/tomography12040058
BibTeX
@article{Amadu2026,
author = {Amadu, Antonio Matteo and Contena, Alessio and Dessì, Alberto and Piscopo, Leandra and Solinas, Emma and Turilli, Davide and Fanni, Salvatore Claudio and Scaglione, Mariano and Masala, Salvatore},
title = {Utility of Native T1 Mapping for the Evaluation of Myocardial Iron Overload in Patients with Thalassemia Major},
journal = {Tomography},
year = {2026},
volume = {12},
number = {4},
pages = {58},
doi = {10.3390/tomography12040058}
}
EUVIMED