Correlation study between magnetic resonance imaging-quantitated cardiac iron deposition and left ventricular function in patients with β-thalassemia major in China
Science Progress · 2025
DOI: 10.1177/00368504251318196 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Progress, 2025. Verfasst von Shuai Peng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, People's Republic of…. Hauptthemen laut MEDLINE: beta-Thalassemia, Ventricular Function, Left, Magnetic Resonance Imaging, Iron. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: the Natural Science Foundations of China.
Abstract (Originalsprache)
Objective
To explore the correlation between cardiac iron deposition and left ventricular function indicators, such as left ventricular end-diastolic volume index, left ventricular end-systolic volume index, and left ventricular ejection fraction, and to evaluate the accuracy of predicting patients with cardiac iron deposition by using left ventricular ejection fraction as an index.
Methods
This quantitative cross-sectional study involved one hundred and fifty transfusion-dependent patients with β-thalassemia major who were evaluated by magnetic resonance imaging to obtain T 2 * values, left ventricular end-diastolic volume index, left ventricular end-systolic volume index, and left ventricular ejection fraction. The relationship between cardiac R 2 * values and left ventricular end-diastolic volume index, left ventricular end-systolic volume index, and left ventricular ejection fraction was analyzed.
Results
Out of the 150 patients, cardiac iron overload was not observed for 92 patients, 42 patients exhibited mild to moderate cardiac iron overload, and 16 patients were severe cardiac iron overloaded. A linear correlation was not observed between the cardiac R 2 * values and left ventricular end-diastolic volume index, left ventricular end-systolic volume index, and left ventricular ejection fraction ( P > 0.05). For the left ventricular ejection fraction index, the sensibility, specificity, positive predictive value, negative predictive value, and the agreement rate were 83.3%, 63.2%, 8.6%, 98.9%, and 64.0%, respectively; also, the area under the receiver operating characteristic curve was 0.348.
Conclusions
A linear correlation was not observed between cardiac R 2 * values and left ventricular end-diastolic volume index, left ventricular end-systolic volume index, and left ventricular ejection fraction in patients with β-thalassemia major. Therefore, using left ventricular ejection fraction as an indirect index to predict cardiac iron deposition may be not reliable in clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, People's Republic of China.
- NHC Key Laboratory of Thalassemia Medicine (Guangxi Medical University), Guangxi Zhuang Autonomous Region, Nanning, People's Republic of China.
- Department of Haematology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, People's Republic of China.
ORCID-Profile: Shuai Peng, Fengming Xu
Förderung
- the Natural Science Foundations of China
Zitieren
APA
Peng, S., Xu, F., Yang, G., Zhang, Y., Tang, Q., Liu, R., & Peng, P. (2025). Correlation study between magnetic resonance imaging-quantitated cardiac iron deposition and left ventricular function in patients with β-thalassemia major in China. Science Progress. https://doi.org/10.1177/00368504251318196
Vancouver
Peng S, Xu F, Yang G, Zhang Y, Tang Q, Liu R, et al. Correlation study between magnetic resonance imaging-quantitated cardiac iron deposition and left ventricular function in patients with β-thalassemia major in China. Science Progress. 2025. doi:10.1177/00368504251318196
BibTeX
@article{Peng2025,
author = {Peng, Shuai and Xu, Fengming and Yang, Guangxin and Zhang, Yanyan and Tang, Qin and Liu, Rongrong and Peng, Peng},
title = {Correlation study between magnetic resonance imaging-quantitated cardiac iron deposition and left ventricular function in patients with β-thalassemia major in China},
journal = {Science Progress},
year = {2025},
doi = {10.1177/00368504251318196}
}
EUVIMED