Standardized Images and Evaluation Metrics for Tomography
Tomography · 01.04.2026 · 12 (4) · 49
DOI: 10.3390/tomography12040049 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, online erschienen am 01.04.2026. Verfasst von Anna Frixou und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Cyprus Institute, 2121 Nicosia, Cyprus. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Tomography, Emission-Computed, Single-Photon. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innovation Foundation under the project PERSPECT.
Abstract (Originalsprache)
Background/Objectives: Modern tomographic reconstruction methods—including physics-informed and AI-based approaches—can produce very high fidelity images. In this regime, widely used global image quality metrics often approach saturation, making it harder to distinguish residual differences between methods and identify remaining performance gaps. This study introduces a physically grounded and standardized evaluation framework designed to retain sensitivity beyond conventional global metrics and support both comparison and systematic improvement in tomographic reconstruction methods.
Methods
The proposed framework defines standardized reference images—“Source”, “Detector”, “Ideal”, and “Realistic”—using Monte Carlo simulations, with the Ideal Image serving as a physically grounded benchmark. Reconstruction performance is evaluated using pixel-wise difference and χ2 maps, Region-of-Interest analysis, intensity (gray-value) histogram comparisons, and the Structure and Contrast Index (SCI), computed on difference maps. Demonstrations use simulated SPECT data reconstructed with ART, MLEM, and RISE-1.
Results
Across case studies, SCI and χ2-based diagnostics reveal structured residuals and localized deficiencies not evident from global similarity metrics such as SSIM or NMSE. Comparative analyses show that methods with similar global scores can exhibit distinct residual structures and region-specific performance variations, while improved agreement in the sinogram domain does not necessarily translate into improved image fidelity. Histogram-based diagnostics provide complementary information on intensity redistribution not captured by pixel-domain summaries.
Conclusions
The framework provides a reproducible, physically meaningful, and sensitive approach for evaluating tomographic reconstruction performance in the high-fidelity regime. By combining standardized reference images with multi-domain and multi-metric analysis, it enables robust benchmarking and supports physically consistent interpretation of reconstruction quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Cyprus Institute, 2121 Nicosia, Cyprus.
- Department of Mechanical Engineering, Frederick University, 1036 Nicosia, Cyprus.
- Frederick Research Center, 1036 Nicosia, Cyprus.
- Department of Physics, National and Kapodistrian University of Athens, 15771 Athens, Greece.
- The Cyprus Academy of Sciences, Letters and Arts, 1522 Nicosia, Cyprus.
ORCID-Profile: Anna Frixou, Theodoros Leontiou, Efstathios Stiliaris, Costas N Papanicolas
Förderung
- Innovation Foundation under the project PERSPECT
Zitieren
APA
Frixou, A., Leontiou, T., Stiliaris, E., & Papanicolas, C. N. (2026). Standardized Images and Evaluation Metrics for Tomography. Tomography, 12(4), 49. https://doi.org/10.3390/tomography12040049
Vancouver
Frixou A, Leontiou T, Stiliaris E, Papanicolas CN. Standardized Images and Evaluation Metrics for Tomography. Tomography. 2026;12(4):49. doi:10.3390/tomography12040049
BibTeX
@article{Frixou2026,
author = {Frixou, Anna and Leontiou, Theodoros and Stiliaris, Efstathios and Papanicolas, Costas N},
title = {Standardized Images and Evaluation Metrics for Tomography},
journal = {Tomography},
year = {2026},
volume = {12},
number = {4},
pages = {49},
doi = {10.3390/tomography12040049}
}