Artifact‐free partial volume correction for 177 Lu‐PSMA SPECT

Yibin Liu, Zhonglin Lu, Gefei Chen, Qiu Huang, Ali Afshar-Oromieh, Axel Rominger, Kuangyu Shi, Greta S P Mok

Medical Physics · 2026-01 · 53 (1)

DOI: 10.1002/mp.70218 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 22.12.2025. Verfasst von Yibin Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa…. Hauptthemen laut MEDLINE: Lutetium, Artifacts, Image Processing, Computer-Assisted, Radioisotopes. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, University of Macau and University of Macau Development Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Partial volume effect degrades the quantification accuracy of SPECT across the field‐of‐view at varying extent. However, traditional partial volume corrections (PVCs) usually apply a spatially invariant point spread function and deconvolution‐based PVC may cause Gibbs ringing artifacts.

Purpose

We aim to develop a spatially variant PSF (svPSF) enhanced PVC without Gibbs ringing artifact and noise amplification for 177 Lu‐PSMA SPECT.

Methods

The svPSFs were generated through linear interpolations of Monte Carlo simulated 177 Lu point sources across the field‐of‐view. Reblurred Van Cittert (RVC) and iterative Yang (IY) were enhanced by applying svPSFs voxel by voxel. In RVC, the non‐negativity constraint (NC) was further implemented by scaling the negative values in the intermediate images with an empirical coefficient. All PVC methods were validated via simulated SPECT data using a digital geometrical cylindrical phantom with five spheres and 20 XCAT phantoms, as well as real sequential 177 Lu‐PSMA‐617 SPECT data of 10 clinical patients. Coefficient of variation (CoV) was measured on a uniform background on the geometrical phantom. Recovery coefficients (RC) of spheres and mean absolute activity errors (MAE) of the kidneys, parotid glands, and tumors in XCAT phantoms were evaluated, while the activity difference was evaluated in clinical data before and after PVC.

Results

For the cylindrical phantom, the central sphere suffered from a more severe partial volume effect (RC of 0.50) than one of the peripheral spheres on the edge of the phantom (RC of 0.63). Their RCs were improved to 1.02 and 1.22 after IY, 1.03 and 0.98 after svPSF‐IY, 1.02 and 1.15 after RVC, 0.99 and 1.12 after NC‐RVC, and 0.98 and 1.01 after svPSF+NC‐RVC, respectively. The background CoV was 0.048 for non‐PVC, 0.090 for RVC, 0.078 for NC‐RVC, and 0.082 for svPSF+NC‐RVC. The MAEs of kidneys, parotid glands, and tumors before PVC were 20.4% ± 1.1%, 51.2% ± 6.1%, and 51.8% ± 8.1% respectively, and were best reduced to 4.7% ± 2.4%, 6.2% ± 4.5%, and 8.8% ± 6.4% after svPSF‐IY. The Gibbs ringing artifacts and noise in RVC were reduced when NC was implemented. The activity differences of clinical data showed a similar trend with those of XCAT simulations.

Conclusions

The proposed svPSF enhanced PVC methods improve quantification accuracy in 177 Lu‐PSMA‐617 SPECT. NC suppresses the Gibbs ringing artifacts and reduces noise in standard RVC images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LutetiumArtifactsImage Processing, Computer-AssistedRadioisotopesTomography, Emission-Computed, Single-PhotonHeterocyclic Compounds, 1-RingDipeptidesPhantoms, ImagingHumansMonte Carlo Method

Stichwörter der Autor:innen

177Lu‐PSMA‐617SPECT/CTpartial volume correctionspatially variant point spread function

Substanzen

LutetiumRadioisotopesLutetium-177Heterocyclic Compounds, 1-RingDipeptides

Autor:innen und Institutionen

  • Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau, SAR, China.
  • Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • Treatment Planning System Department, Jiangsu Rayer Medical Technology Company Ltd., Wuxi, China.
  • Centre for Artificial Intelligence Driven Drug Discovery, Faculty of Applied Sciences, Macao Polytechnic University, Macau, SAR, China.
  • Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Ministry of Education Frontiers Science Center for Precision Oncology, Faculty of Health Science, University of Macau, Taipa, Macau, SAR, China.

Förderung

  • National Natural Science Foundation of China
  • University of Macau and University of Macau Development Foundation

Zitieren

APA

Liu, Y., Lu, Z., Chen, G., Huang, Q., Afshar-Oromieh, A., Rominger, A., Shi, K., & Mok, G. S. P. (2026). Artifact‐free partial volume correction for 177 Lu‐PSMA SPECT. Medical Physics, 53(1). https://doi.org/10.1002/mp.70218

Vancouver

Liu Y, Lu Z, Chen G, Huang Q, Afshar-Oromieh A, Rominger A, et al. Artifact‐free partial volume correction for 177 Lu‐PSMA SPECT. Medical Physics. 2026;53(1). doi:10.1002/mp.70218

BibTeX
@article{Liu2026,
  author = {Liu, Yibin and Lu, Zhonglin and Chen, Gefei and Huang, Qiu and Afshar-Oromieh, Ali and Rominger, Axel and Shi, Kuangyu and Mok, Greta S P},
  title = {Artifact‐free partial volume correction for 177 Lu‐PSMA SPECT},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {1},
  doi = {10.1002/mp.70218}
}
Kostenlos starten →