Super-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging
Tomography · 2026
DOI: 10.3390/tomography12010007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, 2026. Verfasst von Yusuke Kobayashi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Graduate School of Medicine, Ehime University, Toon 791-0295, Japan. Hauptthemen laut MEDLINE: Deep Learning, Myocardial Perfusion Imaging, Coronary Artery Disease, Tomography, X-Ray Computed. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Super-resolution deep-learning reconstruction (SR-DLR) is an advanced image reconstruction technique, but its effect on dynamic myocardial computed tomography perfusion (CTP) imaging has not been evaluated. This study aimed to examine the impact of SR-DLR on image quality and perfusion parameters in dynamic myocardial CTP.
Methods
Thirty-five patients who underwent dynamic myocardial CTP for coronary artery disease assessment were retrospectively analyzed. Two CTP datasets were reconstructed using hybrid iterative reconstruction (HIR) and SR-DLR. Image quality was compared qualitatively and quantitatively, including image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge rise slope (ERS). Equivalence of CT-derived myocardial blood flow (CT-MBF) between two reconstructions was tested using a previously reported 15% equivalence margin. Intra-patient variability of CT-MBF was evaluated using the robust coefficient of variation (rCV).
Results
In the qualitative assessment, SR-DLR had significantly higher scores in contrast (4.0 vs. 2.0) and sharpness (4.5 vs. 2.5) compared with HIR (p < 0.001), while contrast scores were similar. In the quantitative assessment, SR-DLR demonstrated significantly lower image noise (19.4 vs. 29.4 HU), and improved SNR (6.1 vs. 4.1), CNR (13.7 vs. 10.9), and ERS (171.0 vs. 135.1 HU/mm) (all p < 0.001). Mean global CT-MBF was comparable (3.15 ± 0.91 mL/g/min for HIR vs. 3.18 ± 0.97 mL/g/min for SR-DLR) and equivalence was confirmed (p = 0.022). SR-DLR significantly reduced rCV compared with HIR (36.0% vs. 41.0%, p < 0.001).
Conclusions
SR-DLR enhances image quality in dynamic myocardial CTP while maintaining mean global CT-MBF and reducing intra-patient variability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Graduate School of Medicine, Ehime University, Toon 791-0295, Japan.
- Department of Radiology, Ehime Prefectural Imabari Hospital, Imabari 794-0006, Japan.
- Canon Medical Systems Corporation, Otawara 324-8550, Japan.
- Department of Cardiology, Pulmonology, Hypertension, and Nephrology, Graduate School of Medicine, Ehime University, Toon 791-0295, Japan.
ORCID-Profile: Yusuke Kobayashi, Yuki Tanabe, Kentaro Ohara, Takaaki Hosokawa, Shota Nakano, Teruhito Kido
Zitieren
APA
Kobayashi, Y., Tanabe, Y., Morikawa, T., Yoshida, K., Ohara, K., Hosokawa, T., Kouchi, T., Nakano, S., Yamaguchi, O., & Kido, T. (2026). Super-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging. Tomography. https://doi.org/10.3390/tomography12010007
Vancouver
Kobayashi Y, Tanabe Y, Morikawa T, Yoshida K, Ohara K, Hosokawa T, et al. Super-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging. Tomography. 2026. doi:10.3390/tomography12010007
BibTeX
@article{Kobayashi2026,
author = {Kobayashi, Yusuke and Tanabe, Yuki and Morikawa, Tomoro and Yoshida, Kazuki and Ohara, Kentaro and Hosokawa, Takaaki and Kouchi, Takanori and Nakano, Shota and Yamaguchi, Osamu and Kido, Teruhito},
title = {Super-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging},
journal = {Tomography},
year = {2026},
doi = {10.3390/tomography12010007}
}
EUVIMED