EUVIMEDEUVIMED entdecken
ValidierungsstudieMultizentrische Studie

Cross-institutional validation of a polar map-free 3D deep learning model for obstructive coronary artery disease prediction using myocardial perfusion imaging: insights into generalizability and bias

Yu-Cheng Shih, Chi-Lun Ko, Shan-Ying Wang, Chen-Yu Chang, Shau-Syuan Lin, Cheng-Wen Huang, Mei-Fang Cheng, Chung-Ming Chen, Yen-Wen Wu iD

European Journal of Nuclear Medicine and Molecular Imaging · 2025-09 · 52 (11) · 4213-4223

DOI: 10.1007/s00259-025-07243-w ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 08.04.2025. Verfasst von Yu-Cheng Shih und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Deep Learning, Coronary Artery Disease, Imaging, Three-Dimensional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Ministry of Science and Technology, Taiwan, Far Eastern Memorial Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Deep learning (DL) models for predicting obstructive coronary artery disease (CAD) using myocardial perfusion imaging (MPI) have shown potential for enhancing diagnostic accuracy. However, their ability to maintain consistent performance across institutions and demographics remains uncertain. This study aimed to investigate the generalizability and potential biases of an in-house MPI DL model between two hospital-based cohorts. METHODS: We retrospectively included patients from two medical centers in Taiwan who underwent stress/redistribution thallium-201 MPI followed by invasive coronary angiography within 90 days as the reference standard. A polar map-free 3D DL model trained on 928 MPI images from one center to predict obstructive CAD was tested on internal (933 images) and external (3234 images from the other center) validation sets. Diagnostic performance, assessed using area under receiver operating characteristic curves (AUCs), was compared between the internal and external cohorts, demographic groups, and with the performance of stress total perfusion deficit (TPD). RESULTS: The model showed significantly lower performance in the external cohort compared to the internal cohort in both patient-based (AUC: 0.713 vs. 0.813) and vessel-based (AUC: 0.733 vs. 0.782) analyses, but still outperformed stress TPD (all p < 0.001). The performance was lower in patients who underwent treadmill stress MPI in the internal cohort and in patients over 70 years old in the external cohort. CONCLUSIONS: This study demonstrated adequate performance but also limitations in the generalizability of the DL-based MPI model, along with biases related to stress type and patient age. Thorough validation is essential before the clinical implementation of DL MPI models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial Perfusion ImagingDeep LearningCoronary Artery DiseaseImaging, Three-DimensionalHumansMaleFemaleMiddle AgedRetrospective StudiesAgedBias

Stichwörter der Autor:innen

BiasCoronary artery disease (CAD)Deep learning (DL)GeneralizabilityMyocardial perfusion imaging (MPI)Single-photon emission tomography (SPECT)

Autor:innen und Institutionen

  • Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
  • Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan.
  • Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan.
  • College of Medicine, National Taiwan University, Taipei, Taiwan.
  • Electrical and Communication Engineering College, Yuan Ze University, Taoyuan, Taiwan.
  • Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan. wuyw0502@gmail.com.

ORCID-Profile: Yen-Wen Wu

Förderung

  • Ministry of Science and Technology, Taiwan
  • Far Eastern Memorial Hospital

Zitieren

APA

Shih, Y. C., Ko, C. L., Wang, S. Y., Chang, C. Y., Lin, S. S., Huang, C. W., Cheng, M. F., Chen, C. M., & Wu, Y. W. (2025). Cross-institutional validation of a polar map-free 3D deep learning model for obstructive coronary artery disease prediction using myocardial perfusion imaging: insights into generalizability and bias. European Journal of Nuclear Medicine and Molecular Imaging, 52(11), 4213-4223. https://doi.org/10.1007/s00259-025-07243-w

Vancouver

Shih YC, Ko CL, Wang SY, Chang CY, Lin SS, Huang CW, et al. Cross-institutional validation of a polar map-free 3D deep learning model for obstructive coronary artery disease prediction using myocardial perfusion imaging: insights into generalizability and bias. European Journal of Nuclear Medicine and Molecular Imaging. 2025;52(11):4213-4223. doi:10.1007/s00259-025-07243-w

BibTeX
@article{Shih2025,
  author = {Shih, Yu-Cheng and Ko, Chi-Lun and Wang, Shan-Ying and Chang, Chen-Yu and Lin, Shau-Syuan and Huang, Cheng-Wen and Cheng, Mei-Fang and Chen, Chung-Ming and Wu, Yen-Wen},
  title = {Cross-institutional validation of a polar map-free 3D deep learning model for obstructive coronary artery disease prediction using myocardial perfusion imaging: insights into generalizability and bias},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  volume = {52},
  number = {11},
  pages = {4213--4223},
  doi = {10.1007/s00259-025-07243-w}
}
Kostenlos starten →