EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Visibility of Intracranial Perforating Arteries Using Ultra-High-Resolution Photon-Counting Detector Computed Tomography (CT) Angiography

Takashi Okazaki iD, Tetsu Niwa iD, Ryoichi Yoshida, Takatoshi Sorimachi, Jun Hashimoto iD

Tomography · 2024

DOI: 10.3390/tomography10120136 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, 2024. Verfasst von Takashi Okazaki und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Signal-To-Noise Ratio. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Photon-counting detector computed tomography (PCD-CT) offers energy-resolved CT data with enhanced resolution, reduced electronic noise, and improved tissue contrast. This study aimed to evaluate the visibility of intracranial perforating arteries on ultra-high-resolution (UHR) CT angiography (CTA) on PCD-CT.

Methods

A retrospective analysis of intracranial UHR PCD-CTA was performed for 30 patients. The image quality from four UHR PCD-CTA reconstruction methods [kernel Hv40 and Hv72, with and without quantum iterative reconstruction (QIR)] was assessed for the lenticulostriate arteries (LSAs) and pontine arteries (PAs). A subjective evaluation included peripheral visibility, vessel sharpness, and image noise, while objective analysis focused on the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR).

Results

Peripheral LSAs were well visualized across all reconstruction methods, with no significant differences between them. Vessel sharpness and image noise varied significantly (p < 0.0001); sharper LSAs and more noise were seen with kernel Hv72 compared to kernel Hv40 (p < 0.05). A similar pattern was observed for PAs, though peripheral visibility was lower than that for LSAs. The SNR and CNR were the highest in the presence of kernel Hv72 with QIR, and lowest with kernel Hv72 without QIR, compared to kernel Hv40 (p < 0.05).

Conclusions

UHR PCD-CTA provided a good visualization of the intracranial perforating arteries, particularly LSAs. The vessel sharpness and image noise varied by reconstruction method, in which kernel Hv72 with QIR offered the optimal visualization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographySignal-To-Noise RatioHumansRetrospective StudiesFemaleMaleMiddle AgedAdultAgedPhotonsCerebral AngiographyCerebral ArteriesRadiographic Image Interpretation, Computer-AssistedAged, 80 and overImage Processing, Computer-Assisted

Stichwörter der Autor:innen

CT angiographyintracranial perforating arteriesphoton-counting detector CTultra-high-resolution CT

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.
  • Department of Radiology, Tokai University Hospital, 143 Shimokasuya, Isehara 259-1193, Japan.
  • Department of Neurosurgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.

ORCID-Profile: Takashi Okazaki, Tetsu Niwa, Jun Hashimoto

Zitieren

APA

Okazaki, T., Niwa, T., Yoshida, R., Sorimachi, T., & Hashimoto, J. (2024). Visibility of Intracranial Perforating Arteries Using Ultra-High-Resolution Photon-Counting Detector Computed Tomography (CT) Angiography. Tomography. https://doi.org/10.3390/tomography10120136

Vancouver

Okazaki T, Niwa T, Yoshida R, Sorimachi T, Hashimoto J. Visibility of Intracranial Perforating Arteries Using Ultra-High-Resolution Photon-Counting Detector Computed Tomography (CT) Angiography. Tomography. 2024. doi:10.3390/tomography10120136

BibTeX
@article{Okazaki2024,
  author = {Okazaki, Takashi and Niwa, Tetsu and Yoshida, Ryoichi and Sorimachi, Takatoshi and Hashimoto, Jun},
  title = {Visibility of Intracranial Perforating Arteries Using Ultra-High-Resolution Photon-Counting Detector Computed Tomography (CT) Angiography},
  journal = {Tomography},
  year = {2024},
  doi = {10.3390/tomography10120136}
}
Kostenlos starten →