Fully Native DPL-Based Conductor Sizing Optimization for Distribution Networks in DIgSILENT PowerFactory

Víctor Mario Vélez-Marín, Oscar Danilo Montoya, Jesús C. Hernández

Technologies · 2026-08-02 · 14 (8) · 477

DOI: 10.3390/technologies14080477 ↗

At a glance

Journal article in Technologies, published online on 2026-08-02. Written by Víctor Mario Vélez-Marín and 2 co-authors. 41 references. The full text is freely available (open access, CC BY 4.0).

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

This paper presents a fully native optimization framework, implemented within DIgSILENT PowerFactory, which is aimed at solving the optimal conductor sizing problem (OCSP) in electrical distribution systems under realistic operating conditions. Our methodology integrates a tabu search algorithm (TSA) directly with the three-phase power flow routines and database objects available in the DigSILENT programming language (DPL), thereby eliminating the need for external data exchange and synchronization between independent optimization and network simulation environments. Our framework considers balanced and unbalanced operating conditions while incorporating peak demand, multilevel demand, and hourly demand load profiles. The optimization process minimizes annual investment and operating costs while satisfying voltage regulation and conductor ampacity constraints. The methodology was validated using a 27-bus benchmark system and the IEEE 33- and 123-bus distribution systems under different operating scenarios. The numerical results indicate that chronological demand scenarios significantly influence conductor allocation decisions and annual operating costs. Compared to the conventional peak demand load profile, the multilevel and hourly load profiles produced lower annual costs by distributing conductor sizing decisions across multiple operating states instead of considering worst-case loading conditions. Additionally, the unbalanced scenarios increased the operating losses and modified the conductor selection patterns due to unequal phase loading and current asymmetries. The proposed TSA-DPL implementation maintained stable convergence behavior and low statistical dispersion under all the evaluated benchmark systems and operating conditions. Even for the IEEE 123-bus feeder under unbalanced hourly operating conditions, the standard deviation remained below 0.70% of the average annual cost, confirming the robustness and repeatability of the methodology. Although the detailed three-phase chronological simulations increased the computational requirements, the proposed implementation demonstrated computational applicability to the evaluated benchmark systems. Overall, the proposed TSA-DPL framework constitutes a robust native implementation for realistic conductor sizing studies in modern three-phase distribution systems.

Cite

APA

Vélez-Marín, V. M., Montoya, O. D., & Hernández, J. C. (2026). Fully Native DPL-Based Conductor Sizing Optimization for Distribution Networks in DIgSILENT PowerFactory. Technologies, 14(8), 477. https://doi.org/10.3390/technologies14080477

Vancouver

Vélez-Marín VM, Montoya OD, Hernández JC. Fully Native DPL-Based Conductor Sizing Optimization for Distribution Networks in DIgSILENT PowerFactory. Technologies. 2026;14(8):477. doi:10.3390/technologies14080477

BibTeX
@article{VlezMarn2026,
  author = {Vélez-Marín, Víctor Mario and Montoya, Oscar Danilo and Hernández, Jesús C.},
  title = {Fully Native DPL-Based Conductor Sizing Optimization for Distribution Networks in DIgSILENT PowerFactory},
  journal = {Technologies},
  year = {2026},
  volume = {14},
  number = {8},
  pages = {477},
  doi = {10.3390/technologies14080477}
}
Start for free →