Development of a Low-Cost Multi-Physiological Signal Simulation System for Multimodal Wearable Device Calibration

Tumenkhuslen Delgerkhaan, Qun Wei, Jiwoo Jung, Sangwon Lee, Gangoh Na, Bongjo Kim, In-Cheol Kim, Heejoon Park

Technologies · 2025-06-10 · 13 (6) · 239

DOI: 10.3390/technologies13060239 ↗

At a glance

Journal article in Technologies, published online on 2025-06-10. Written by Tumenkhuslen Delgerkhaan and 7 co-authors. Cited 2 times so far (Crossref); 27 references. The full text is freely available (open access, CC BY 4.0). Funded by: Startup Growth Technology Development, Ministry of SMEs and Startups (MSS, Korea).

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Using multimodal wearable devices to diagnose cardiovascular diseases early is essential for providing timely medical assistance, particularly in remote areas. This approach helps prevent risks and reduce mortality rates. However, prolonged use of medical devices can lead to measurement inaccuracies, necessitating calibration to maintain precision. Unfortunately, wearable devices often lack affordable calibrators that are suitable for personal use. This study introduces a low-cost simulation system for phonocardiography (PCG) and photoplethysmography (PPG) signals designed for a multimodal smart stethoscope calibration. The proposed system was developed using a multicore microprocessor (MCU), two digital-to-analog converters (DACs), an LED light, and a speaker. It synchronizes dual signals by assigning tasks based on a multitasking function. A designed time adjustment algorithm controls the pulse transit time (PTT) to simulate various cardiovascular conditions. The simulation signals are generated from preprocessed PCG and PPG signals collected during in vivo experiments. A prototype device was manufactured to evaluate performance by measuring the generated signal using an oscilloscope and a multimodal smart stethoscope. The preprocessed signals, generated signals, and measurements by the smart stethoscope were compared and evaluated through correlation analysis. The experimental results confirm that the proposed system accurately generates the features of the physiological signals and remains in phase with the original signals.

Funding

  • Startup Growth Technology Development
  • Ministry of SMEs and Startups (MSS, Korea)

Cite

APA

Delgerkhaan, T., Wei, Q., Jung, J., Lee, S., Na, G., Kim, B., Kim, I., & Park, H. (2025). Development of a Low-Cost Multi-Physiological Signal Simulation System for Multimodal Wearable Device Calibration. Technologies, 13(6), 239. https://doi.org/10.3390/technologies13060239

Vancouver

Delgerkhaan T, Wei Q, Jung J, Lee S, Na G, Kim B, et al. Development of a Low-Cost Multi-Physiological Signal Simulation System for Multimodal Wearable Device Calibration. Technologies. 2025;13(6):239. doi:10.3390/technologies13060239

BibTeX
@article{Delgerkhaan2025,
  author = {Delgerkhaan, Tumenkhuslen and Wei, Qun and Jung, Jiwoo and Lee, Sangwon and Na, Gangoh and Kim, Bongjo and Kim, In-Cheol and Park, Heejoon},
  title = {Development of a Low-Cost Multi-Physiological Signal Simulation System for Multimodal Wearable Device Calibration},
  journal = {Technologies},
  year = {2025},
  volume = {13},
  number = {6},
  pages = {239},
  doi = {10.3390/technologies13060239}
}
Start for free →