A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances

Fatih Evran

Symmetry · 2026-11-17 · 18 (11) · 1925

DOI: 10.3390/sym18111925 ↗

At a glance

Journal article in Symmetry, published online on 2026-11-17. Written by Fatih Evran. 40 references. The full text is freely available (open access, CC BY 4.0). Funded by: Scientific and Technological Research Council of Türkiye.

AstrattDettalji biblijografiċiCiteRelated studies

Abstract (original language)

This study presents an adaptive RST polynomial control framework for nonideal DC–DC buck converters under line and load disturbances, explicitly accounting for pulse-width modulation (PWM) update delay. RST refers to a polynomial control structure comprising the R, S, and T polynomials. Conventional fixed-gain controllers are typically designed around a nominal operating point and may therefore lead to degraded voltage regulation, larger transient deviations, increased current stress, and reduced disturbance-rejection capability when converter dynamics vary due to load changes, input-voltage disturbances, parasitic losses, and digital implementation delays. Fixed-parameter model-based polynomial controllers may also fail to preserve the desired closed-loop dynamics when the effective converter parameters vary with the operating condition. To address these limitations, a nonideal averaged model is used to obtain an affine discrete-time input–output representation, and the effective PWM update delay is incorporated into the RST pole-placement design. The plant is identified online using a bias-augmented autoregressive with exogenous input (ARX) model with forgetting-factor recursive least squares (RLS), where the affine term separates constant operating-point and quasi-static mismatch effects from dynamic coefficients. The RST polynomials are recomputed online through a Diophantine equation, with an integral factor included for offset rejection and constant-reference tracking. The controller is experimentally evaluated on a buck converter prototype and compared with a fixed-gain proportional–integral (PI) controller under start-up, load-resistance transitions, and input-voltage transitions. In the start-up test, inductor-current overshoot is reduced from 62.5% to 12.5%, and start-up time decreases from 16.7ms to 1.6ms. For the 48V to 70V input-voltage transition, voltage overshoot decreases from 6.7V to 0.2V. The results show improved transient shaping, lower current stress, and faster recovery compared with the fixed-gain PI controller under line and load disturbances.

Funding

  • Scientific and Technological Research Council of Türkiye

Cite

APA

Evran, F. (2026). A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances. Symmetry, 18(11), 1925. https://doi.org/10.3390/sym18111925

Vancouver

Evran F. A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances. Symmetry. 2026;18(11):1925. doi:10.3390/sym18111925

BibTeX
@article{Evran2026,
  author = {Evran, Fatih},
  title = {A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances},
  journal = {Symmetry},
  year = {2026},
  volume = {18},
  number = {11},
  pages = {1925},
  doi = {10.3390/sym18111925}
}
Start for free →