Adaptive Instantaneous Frequency Synchrosqueezing Transform and Enhanced AdaBoost for Power Quality Disturbance Detection
Symmetry · 10.03.2026 · 18 (3) · 475
DOI: 10.3390/sym18030475 ↗Kurz gefasst
Fachartikel in der Zeitschrift Symmetry, online erschienen am 10.03.2026. Verfasst von Chencheng He und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hubei Province Key Laboratory of System Science in Metallurgical Process, The 14th Five Year Plan” Hubei Provincial advantaged characteristic disciplines (groups) project of Wuhan University of Science and Technology.
Abstract (Originalsprache)
The integration of renewable energy and power electronics has intensified the occurrence of complex power quality disturbances (PQDs), which increasingly threaten grid stability. To address the challenges of multi-class PQD identification under noisy conditions, this paper proposes a novel framework that combines an enhanced time–frequency analysis method with an optimized AdaBoost decision tree. The main contributions are three-fold: (1) We develop an instantaneous frequency adaptive Fourier synchrosqueezing transform (IFAFSST) equipped with a custom adaptive operator that aligns closely with the frequency modulation patterns in PQD signals, thereby improving time–frequency energy localization. (2) The IFAFSST outputs are decomposed into low-frequency and high-frequency components, from each of which a set of 16 discriminative features is extracted. (3) An improved AdaBoost classifier is introduced, incorporating forward feature selection and Hyperband-based hyperparameter optimization to enhance classification performance. Hyperband accelerates the optimization process by dynamically allocating computing resources and iteratively eliminating suboptimal configurations, thereby enabling efficient determination of the optimal hyperparameters. The method proposed in this paper achieved an accuracy rate of 99.50% on simulated data containing 30 dB white noise and 98.30% on hardware platform data. This framework can effectively handle 23 types of interference, including seven types of single interference, 12 types of double compound interference, three types of triple compound interference, and one type of quadruple compound interference. It performs particularly well in identifying composite interference scenarios. This research has made a significant contribution to power quality analysis, providing a powerful solution with high accuracy and practical applicability, and offering great potential for the implementation of smart grid monitoring systems and the integration of renewable energy.
Förderung
- Hubei Province Key Laboratory of System Science in Metallurgical Process
- The 14th Five Year Plan” Hubei Provincial advantaged characteristic disciplines (groups) project of Wuhan University of Science and Technology
Zitieren
APA
He, C., Lu, Y., & Wang, W. (2026). Adaptive Instantaneous Frequency Synchrosqueezing Transform and Enhanced AdaBoost for Power Quality Disturbance Detection. Symmetry, 18(3), 475. https://doi.org/10.3390/sym18030475
Vancouver
He C, Lu Y, Wang W. Adaptive Instantaneous Frequency Synchrosqueezing Transform and Enhanced AdaBoost for Power Quality Disturbance Detection. Symmetry. 2026;18(3):475. doi:10.3390/sym18030475
BibTeX
@article{He2026,
author = {He, Chencheng and Lu, Yuyi and Wang, Wenbo},
title = {Adaptive Instantaneous Frequency Synchrosqueezing Transform and Enhanced AdaBoost for Power Quality Disturbance Detection},
journal = {Symmetry},
year = {2026},
volume = {18},
number = {3},
pages = {475},
doi = {10.3390/sym18030475}
}