EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Collagen-Based Vascular Augmentation and Its Effect on Arterial Sealing Quality in an Ex Vivo Model

Andreas Kirschbaum, Elda Llaha, Florian Kirschbaum, Moritz Jesinghaus, Nikolas Mirow

Surgeries · 10.07.2026 · 7 (3) · 83

DOI: 10.3390/surgeries7030083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgeries, online erschienen am 10.07.2026. Verfasst von Andreas Kirschbaum und 4 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: KLS Martin SE & Co. KG, Tuttlingen, Germany.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Despite modern technology of energy instruments, secure arterial vessel sealing remains a surgical challenge. Particularly in cases of fragile vessel walls or limited visibility, additional reinforcement techniques are potentially desirable. TachoSil®, a collagen-based, fibrin-coated fleece, is routinely employed in clinical practice for hemostasis and suture support. Whether its external use in terms of collagen augmentation improves the burst strength of bipolarly sealed arteries is to be examined.

Objective

To investigate the influence of a TachoSil® cuff on sealing quality and burst pressures after bipolar vessel sealing in a standardized ex vivo model. Materials and Methods: Porcine carotid arteries (outer diameter 5–7 mm) were examined in two groups: native vessels (group A, n = 12) and vessels with TachoSil® cuffs (group B, n = 12). Sealing was performed with marSeal® 5 plus and maXium® sealer. Burst pressures were measured by continuously increasing intraluminal pressure. Histological analyses were performed.

Results

Mean burst pressures were significantly reduced in group B (805 ± 78 mbar) as compared to group A (1452 ± 275 mbar; p < 0.001). Histologically, no structural fusion between vessel walls and collagen fleece was observed.

Conclusions

External collagen augmentation using TachoSil® leads to a significant reduction in the burst strength of bipolarly sealed arteries, despite unaltered sealing duration. The combination of collagen fleece and energy sealing does not have a synergistic effect and should not be used in planned vessel sealing. Further studies are needed to evaluate the underlying mechanisms and possible alternative augmentation strategies.

Förderung

  • KLS Martin SE & Co. KG, Tuttlingen, Germany

Zitieren

APA

Kirschbaum, A., Llaha, E., Kirschbaum, F., Jesinghaus, M., & Mirow, N. (2026). Collagen-Based Vascular Augmentation and Its Effect on Arterial Sealing Quality in an Ex Vivo Model. Surgeries, 7(3), 83. https://doi.org/10.3390/surgeries7030083

Vancouver

Kirschbaum A, Llaha E, Kirschbaum F, Jesinghaus M, Mirow N. Collagen-Based Vascular Augmentation and Its Effect on Arterial Sealing Quality in an Ex Vivo Model. Surgeries. 2026;7(3):83. doi:10.3390/surgeries7030083

BibTeX
@article{Kirschbaum2026,
  author = {Kirschbaum, Andreas and Llaha, Elda and Kirschbaum, Florian and Jesinghaus, Moritz and Mirow, Nikolas},
  title = {Collagen-Based Vascular Augmentation and Its Effect on Arterial Sealing Quality in an Ex Vivo Model},
  journal = {Surgeries},
  year = {2026},
  volume = {7},
  number = {3},
  pages = {83},
  doi = {10.3390/surgeries7030083}
}
Kostenlos starten →