Modified Tension Band Wiring Using Only Non-Absorbable Braided Polyblend Sutures for the Treatment of Patellar Fractures

Annalisa Itro, Annalisa De Cicco, Gianluca Conza, Luca Schiavo, Niccolò Garofalo, Adriano Braile, Francesco Nappi, Giuseppe Toro

Surgical Techniques Development · 2024-06-13 · 13 (2) · 227-236

DOI: 10.3390/std13020015 ↗

At a glance

Journal article in Surgical Techniques Development, published online on 2024-06-13. Written by Annalisa Itro and 7 co-authors. Cited 2 times so far (Crossref); 27 references. The full text is freely available (open access, CC BY 4.0).

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Patellar fractures represent approximately 1% of all fractures and the pattern is influenced by the quality of the bone and the energy of the trauma. Transverse fractures are associated with extensor mechanism failure and interruption of joint congruence. Patellar fractures are generally fixed using tension band principles, through K-wires and metal cerclage. The tension band was conceived to transform the considerable tensile force applied to the patella into a compressive one to obtain a stable fixation. The use of metal implants might be associated with a significant discomfort, mostly related to the irritating action of K-wires and cerclage on the surrounding soft tissues, often leading to the need for implant removal. Therefore, we introduced an original technique for fix patellar fractures by using only a non-adsorbable braided polyblend suture. Postoperative care included progressive range of motion recovery using an articulated knee brace and a specific protocol. The suture-only tension band technique seems to be a useful technique in terms of complications and reoperation rate while allowing secure and early mobilization.

Cite

APA

Itro, A., Cicco, A. D., Conza, G., Schiavo, L., Garofalo, N., Braile, A., Nappi, F., & Toro, G. (2024). Modified Tension Band Wiring Using Only Non-Absorbable Braided Polyblend Sutures for the Treatment of Patellar Fractures. Surgical Techniques Development, 13(2), 227-236. https://doi.org/10.3390/std13020015

Vancouver

Itro A, Cicco AD, Conza G, Schiavo L, Garofalo N, Braile A, et al. Modified Tension Band Wiring Using Only Non-Absorbable Braided Polyblend Sutures for the Treatment of Patellar Fractures. Surgical Techniques Development. 2024;13(2):227-236. doi:10.3390/std13020015

BibTeX
@article{Itro2024,
  author = {Itro, Annalisa and Cicco, Annalisa De and Conza, Gianluca and Schiavo, Luca and Garofalo, Niccolò and Braile, Adriano and Nappi, Francesco and Toro, Giuseppe},
  title = {Modified Tension Band Wiring Using Only Non-Absorbable Braided Polyblend Sutures for the Treatment of Patellar Fractures},
  journal = {Surgical Techniques Development},
  year = {2024},
  volume = {13},
  number = {2},
  pages = {227--236},
  doi = {10.3390/std13020015}
}
Start for free →