EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Signal Processing for Transient Flow Rate Determination: An Analytical Soft Sensor Using Two Pressure Signals

Faras Brumand-Poor, Tim Kotte, Enrico Gaspare Pasquini, Katharina Schmitz

Signals · 02.12.2024 · 5 (4) · 812-840

DOI: 10.3390/signals5040045 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Signals, online erschienen am 02.12.2024. Verfasst von Faras Brumand-Poor und 3 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: research association Forschungskuratorium Maschinenbau e. V. (FKM), Federal Ministry of Economic Affairs and Climate Action.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate knowledge of the flow rate is essential for hydraulic systems, enabling the calculation of hydraulic power when combined with pressure measurements. These data are crucial for applications such as predictive maintenance. However, most flow rate sensors in fluid power systems operate invasively, disrupting the flow and producing inaccurate results, especially under transient conditions. Utilizing pressure transducers represents a non-invasive soft sensor approach since no physical flow rate sensor is used to determine the flow rate. Usually, this approach relies on the Hagen–Poiseuille (HP) law, which is limited to steady and incompressible flow. This paper introduces a novel soft sensor with an analytical model for transient, compressible pipe flow based on two pressure signals. The model is derived by solving fundamental fluid equations in the Laplace domain and converting them back to the time domain. Using the four-pole theorem, this model contains a relationship between the pressure difference and the flow rate. Several unsteady test cases are investigated and compared to a steady soft sensor based on the HP law, highlighting our soft sensor’s promising capability. It exhibits an overall error of less than 0.15% for the investigated test cases in a distributed-parameter simulation, whereas the HP-based sensor shows errors in the double-digit range.

Förderung

  • research association Forschungskuratorium Maschinenbau e. V. (FKM)
  • Federal Ministry of Economic Affairs and Climate Action

Zitieren

APA

Brumand-Poor, F., Kotte, T., Pasquini, E. G., & Schmitz, K. (2024). Signal Processing for Transient Flow Rate Determination: An Analytical Soft Sensor Using Two Pressure Signals. Signals, 5(4), 812-840. https://doi.org/10.3390/signals5040045

Vancouver

Brumand-Poor F, Kotte T, Pasquini EG, Schmitz K. Signal Processing for Transient Flow Rate Determination: An Analytical Soft Sensor Using Two Pressure Signals. Signals. 2024;5(4):812-840. doi:10.3390/signals5040045

BibTeX
@article{BrumandPoor2024,
  author = {Brumand-Poor, Faras and Kotte, Tim and Pasquini, Enrico Gaspare and Schmitz, Katharina},
  title = {Signal Processing for Transient Flow Rate Determination: An Analytical Soft Sensor Using Two Pressure Signals},
  journal = {Signals},
  year = {2024},
  volume = {5},
  number = {4},
  pages = {812--840},
  doi = {10.3390/signals5040045}
}
Kostenlos starten →