EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous COP and sEMG–NMF Assessment of Single-Leg Stance: Distinguishing Reconstruction Quality, Minimum Dimensionality, and Computational Reproducibility

Doyeol Kim, Nayoung Jeong, Hyein Park, Jiin Choi, Taeseok Lee, Seonhong Hwang

Sensors · 23.11.2026 · 26 (23) · 7401

DOI: 10.3390/s26237401 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 23.11.2026. Verfasst von Doyeol Kim und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hoseo University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This pilot study assessed center-of-pressure (COP) outputs and non-negative matrix factorization (NMF) characteristics during single-leg stance. Fifteen healthy young adults performed five 20-s trials with eyes open on a firm floor (EOFF), eyes closed on a firm floor (ECFF), and eyes open on a balance board (EOBB), yielding 225 simultaneous COP and seven-muscle sEMG recordings. EOBB COP was measured at the board–mat interface and represents the participant–board system rather than a mechanically equivalent foot–mat measure. Separate analyses evaluated reconstruction at imposed common K = 4, minimum reconstruction dimensionality (BestK), initialization-to-initialization W reproducibility, and EOFF-referenced W similarity. COP outputs differed among conditions, with the largest recorded values in ECFF. Holm-adjusted tests detected no significant condition effects on common-K reconstruction measures or BestK; this small sample does not establish equivalence. Among 221 BestK trials retained after QC, 91.9% selected K = 1 or 2 under the seven-muscle reconstruction criteria. All 225 trials passed common-K reconstruction QC, but only 152 (67.6%) passed W-reproducibility QC; requiring five rather than three near-optimal solutions reduced this to 127 (56.4%). W similarity described only 149 retained trials from 14 participants. EOFF used a within-condition reference, whereas ECFF and EOBB were compared with EOFF; only nine participants met complete-case requirements, so no inferential W comparison was performed. The findings support separate assessment of reconstruction fit and computational reproducibility. Physiological interpretation and added clinical value remain to be established.

Förderung

  • Hoseo University

Zitieren

APA

Kim, D., Jeong, N., Park, H., Choi, J., Lee, T., & Hwang, S. (2026). Simultaneous COP and sEMG–NMF Assessment of Single-Leg Stance: Distinguishing Reconstruction Quality, Minimum Dimensionality, and Computational Reproducibility. Sensors, 26(23), 7401. https://doi.org/10.3390/s26237401

Vancouver

Kim D, Jeong N, Park H, Choi J, Lee T, Hwang S. Simultaneous COP and sEMG–NMF Assessment of Single-Leg Stance: Distinguishing Reconstruction Quality, Minimum Dimensionality, and Computational Reproducibility. Sensors. 2026;26(23):7401. doi:10.3390/s26237401

BibTeX
@article{Kim2026,
  author = {Kim, Doyeol and Jeong, Nayoung and Park, Hyein and Choi, Jiin and Lee, Taeseok and Hwang, Seonhong},
  title = {Simultaneous COP and sEMG–NMF Assessment of Single-Leg Stance: Distinguishing Reconstruction Quality, Minimum Dimensionality, and Computational Reproducibility},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {23},
  pages = {7401},
  doi = {10.3390/s26237401}
}
Kostenlos starten →