EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis

You-Ruei Hou, Shiuan Lin, Yan-Ci Liu, Yu-An Chen, Yi-Hsuan Lee, Jiu-Jenq Lin, Szu-Hua Chen, Wei-Li Hsu

Sensors · 20.11.2026 · 26 (22) · 7338

DOI: 10.3390/s26227338 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 20.11.2026. Verfasst von You-Ruei Hou und 7 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Health Research Institutes, Taiwan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This randomized crossover study compared immediate responses to different local muscle vibration protocols in 40 adults with knee osteoarthritis. Participants were randomized 1:1 to receive intermittent or continuous vibration first, then crossed over to the alternative protocol after washout. Vibration targeted the vastus medialis during 120 s of sit-to-stand exercise. Intermittent vibration was delivered only during seated and standing holds, whereas continuous vibration was delivered throughout the exercise. Knee joint position sense (JPS) errors were assessed at 20°, 40°, and 60° of flexion using inertial measurement units. Near-infrared spectroscopy recorded prefrontal and muscle hemodynamic responses during JPS testing. Assessments were performed at baseline and after each protocol. Data were analyzed using repeated-measures analysis of variance. Intermittent vibration produced smaller JPS errors than continuous vibration at all angles (1.96° versus 2.87°, 2.17° versus 3.20°, and 2.78° versus 4.72°, respectively, all p ≤ 0.019). Intermittent vibration elicited smaller changes in prefrontal total hemoglobin (0.23 versus 0.66 μM, p < 0.001), muscle oxygenated hemoglobin (2.32 versus 5.53 μM, p = 0.003), and muscle total hemoglobin (2.59 versus 6.13 μM, p = 0.004). Intermittent local muscle vibration produced smaller immediate knee JPS errors, whereas continuous vibration elicited larger hemodynamic responses.

Förderung

  • National Health Research Institutes, Taiwan

Zitieren

APA

Hou, Y., Lin, S., Liu, Y., Chen, Y., Lee, Y., Lin, J., Chen, S., & Hsu, W. (2026). Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis. Sensors, 26(22), 7338. https://doi.org/10.3390/s26227338

Vancouver

Hou Y, Lin S, Liu Y, Chen Y, Lee Y, Lin J, et al. Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis. Sensors. 2026;26(22):7338. doi:10.3390/s26227338

BibTeX
@article{Hou2026,
  author = {Hou, You-Ruei and Lin, Shiuan and Liu, Yan-Ci and Chen, Yu-An and Lee, Yi-Hsuan and Lin, Jiu-Jenq and Chen, Szu-Hua and Hsu, Wei-Li},
  title = {Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {22},
  pages = {7338},
  doi = {10.3390/s26227338}
}
Kostenlos starten →