Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis
Sensors · 20.11.2026 · 26 (22) · 7338
DOI: 10.3390/s26227338 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 20.11.2026. Verfasst von You-Ruei Hou und 7 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Health Research Institutes, Taiwan.
Abstract (Originalsprache)
This randomized crossover study compared immediate responses to different local muscle vibration protocols in 40 adults with knee osteoarthritis. Participants were randomized 1:1 to receive intermittent or continuous vibration first, then crossed over to the alternative protocol after washout. Vibration targeted the vastus medialis during 120 s of sit-to-stand exercise. Intermittent vibration was delivered only during seated and standing holds, whereas continuous vibration was delivered throughout the exercise. Knee joint position sense (JPS) errors were assessed at 20°, 40°, and 60° of flexion using inertial measurement units. Near-infrared spectroscopy recorded prefrontal and muscle hemodynamic responses during JPS testing. Assessments were performed at baseline and after each protocol. Data were analyzed using repeated-measures analysis of variance. Intermittent vibration produced smaller JPS errors than continuous vibration at all angles (1.96° versus 2.87°, 2.17° versus 3.20°, and 2.78° versus 4.72°, respectively, all p ≤ 0.019). Intermittent vibration elicited smaller changes in prefrontal total hemoglobin (0.23 versus 0.66 μM, p < 0.001), muscle oxygenated hemoglobin (2.32 versus 5.53 μM, p = 0.003), and muscle total hemoglobin (2.59 versus 6.13 μM, p = 0.004). Intermittent local muscle vibration produced smaller immediate knee JPS errors, whereas continuous vibration elicited larger hemodynamic responses.
Förderung
- National Health Research Institutes, Taiwan
Zitieren
APA
Hou, Y., Lin, S., Liu, Y., Chen, Y., Lee, Y., Lin, J., Chen, S., & Hsu, W. (2026). Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis. Sensors, 26(22), 7338. https://doi.org/10.3390/s26227338
Vancouver
Hou Y, Lin S, Liu Y, Chen Y, Lee Y, Lin J, et al. Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis. Sensors. 2026;26(22):7338. doi:10.3390/s26227338
BibTeX
@article{Hou2026,
author = {Hou, You-Ruei and Lin, Shiuan and Liu, Yan-Ci and Chen, Yu-An and Lee, Yi-Hsuan and Lin, Jiu-Jenq and Chen, Szu-Hua and Hsu, Wei-Li},
title = {Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis},
journal = {Sensors},
year = {2026},
volume = {26},
number = {22},
pages = {7338},
doi = {10.3390/s26227338}
}
EUVIMED