EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Data-Driven Calibration and Reference-Free Drift Detection for Multi-Modal Sensor Systems

Kishor Arvind Mohandas Sivakumar, Laurent Segers iD, Bruno da Silva iD, Argha Sen iD, Sujay Narayana, R R Venkatesha Prasad iD

Sensors · 06.11.2026 · 26 (21) · 7016

DOI: 10.3390/s26217016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 06.11.2026. Verfasst von Kishor Arvind Mohandas Sivakumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering, Mathematics and Computer Science Department, TU Delft, 2600AA Delft, The Netherlands. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EU Commission, EU Project ENACT.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low-cost multi-modal sensors make high-resolution exposomic and urban-health monitoring affordable, but their data are only as useful as they are trustworthy. Measurement bias, cross-sensitivity, temporal drift and domain shift between devices and sites erode reliability, and reference instruments are rarely available for every sensor. We present a two-part reliability workflow for this realistic setting, in which reference data exist for only a subset of sensors, and evaluate it on five custom multi-modal devices deployed at two Brussels sites (9 to 68 days of data per device). For calibration, we benchmark Multiple Linear Regression, Elastic Net, Random Forest, Gradient Boosting and a Domain Adversarial Neural Network (DANN) for O3, NO2, PM2.5 and PM10 on the source device and on other devices at the same site and at the other site using MAE, RMSE, R2, bias, device-balanced aggregation and block-bootstrap intervals. Tree ensembles achieve the lowest source-device errors for most pollutants, yet for PM10, they lose their advantage over the uncalibrated sensor when transferred, a caution for any deployment that calibrates on one unit. DANN attains the highest mean Calibration Transfer Ratio in the transfer settings, although with the available device pairs, the differences are not statistically significant. For modalities without a reference, a cross-sensor residual monitor combined with statistical detectors reliably flags injected gradual drift in sensors that can be reconstructed from the others (UV bands, PM1, temperature, humidity and CO), while Lux, pressure and VOC remain harder. The monitor detects cross-sensor inconsistency rather than isolating the faulty sensor, and the results reflect an injected fault model, not real sensor ageing. Together, these results give a transparent, reproducible baseline and clear practical guidance for building trustworthy low-cost sensor networks.

Schlagwörter

Stichwörter der Autor:innen

calibrationcalibration transferdomain adaptationdrift detectionenvironmental monitoringlow-cost sensorsmulti-modal sensing

Autor:innen und Institutionen

  • Electrical Engineering, Mathematics and Computer Science Department, TU Delft, 2600AA Delft, The Netherlands.
  • Department of Electronics and Informatics, Vrije Universiteit Brussel, 1050 Brussels, Belgium.
  • Department of Computer Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.
  • Skynetics Pvt. Ltd., Bangalore 560003, India.

ORCID-Profile: Laurent Segers, Bruno da Silva, Argha Sen, R R Venkatesha Prasad

Förderung

  • EU Commission
  • EU Project ENACT

Zitieren

APA

Mohandas Sivakumar, K. A., Segers, L., da Silva, B., Sen, A., Narayana, S., & Prasad, R. R. V. (2026). Data-Driven Calibration and Reference-Free Drift Detection for Multi-Modal Sensor Systems. Sensors, 26(21), 7016. https://doi.org/10.3390/s26217016

Vancouver

Mohandas Sivakumar KA, Segers L, da Silva B, Sen A, Narayana S, Prasad RRV. Data-Driven Calibration and Reference-Free Drift Detection for Multi-Modal Sensor Systems. Sensors. 2026;26(21):7016. doi:10.3390/s26217016

BibTeX
@article{MohandasSivakumar2026,
  author = {Mohandas Sivakumar, Kishor Arvind and Segers, Laurent and da Silva, Bruno and Sen, Argha and Narayana, Sujay and Prasad, R R Venkatesha},
  title = {Data-Driven Calibration and Reference-Free Drift Detection for Multi-Modal Sensor Systems},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {7016},
  doi = {10.3390/s26217016}
}
Kostenlos starten →