EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multi-Objective Evaluation of Wearable-Assisted Radar-Only Rehabilitation Monitoring

Hrithik Majumdar Shibu iD, Seyed-Ali Sadegh-Zadeh iD, Delaram Jarchi iD

Sensors · 04.11.2026 · 26 (21) · 6970

DOI: 10.3390/s26216970 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 04.11.2026. Verfasst von Hrithik Majumdar Shibu und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer Science and Electronic Engineering, University of Essex, Colchester CO4 3SQ, UK. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Radar, Rehabilitation. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Millimetre-wave radar offers contactless exercise sensing, while wearable inertial measurement units (IMUs) can supply privileged training supervision without being required at inference. We study radar-only exercise recognition on the mRI dataset (20 healthy subjects; ten exercises) and distinguish descriptive historical architectures from matched RTPD-Net versus constrained fine-tuning (CFT) comparisons. Historical RTPD-Net, PARETO-RKD, and AURORA-RKD were trained using different budgets, seeds, or corruption settings and cannot establish a preferred method. For a fixed 40-segment test split, the original evaluation reported mean corrupted macro-F1 changing from 0.5332 to 0.6945; a paired re-evaluation of saved checkpoints, using 11 corrupted conditions and five realisations each, instead obtained 0.5370 versus 0.6374 (difference 0.1004). The subject-cluster bootstrap interval, conditional on the same four subjects, was [0.0683, 0.1283], but the exact two-sided subject-level prediction-swap test gave p=0.125 (four independent test subjects), so statistical significance is not established. Five independently generated subject-partition seeds (25 fully retrained folds) produced mean corrupted macro-F1 of 0.5375 for the fold-local RTPD reference versus 0.5449 for the validation-gated policy (mean difference 0.0074); fine-tuning was accepted in 5 of 25 folds. These results demonstrate that the validation gate usually retains the reference and that the observed adaptation gains are not established as broadly useful; they also indicate that robustness benefits are heterogeneous and that larger independent-subject evaluations are necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesRadarRehabilitationHumansExerciseMonitoring, PhysiologicMagnetic Resonance Imaging

Stichwörter der Autor:innen

calibrationcorruption robustnesshuman activity recognitioninertial measurement unitknowledge distillationmmWave radarrehabilitation monitoringsubject-independent evaluation

Autor:innen und Institutionen

  • School of Computer Science and Electronic Engineering, University of Essex, Colchester CO4 3SQ, UK.
  • Department of Computing, University of Staffordshire, Stoke-on-Trent ST4 2DE, UK.

ORCID-Profile: Hrithik Majumdar Shibu, Seyed-Ali Sadegh-Zadeh, Delaram Jarchi

Zitieren

APA

Shibu, H. M., Sadegh-Zadeh, S. A., & Jarchi, D. (2026). Multi-Objective Evaluation of Wearable-Assisted Radar-Only Rehabilitation Monitoring. Sensors, 26(21), 6970. https://doi.org/10.3390/s26216970

Vancouver

Shibu HM, Sadegh-Zadeh SA, Jarchi D. Multi-Objective Evaluation of Wearable-Assisted Radar-Only Rehabilitation Monitoring. Sensors. 2026;26(21):6970. doi:10.3390/s26216970

BibTeX
@article{Shibu2026,
  author = {Shibu, Hrithik Majumdar and Sadegh-Zadeh, Seyed-Ali and Jarchi, Delaram},
  title = {Multi-Objective Evaluation of Wearable-Assisted Radar-Only Rehabilitation Monitoring},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {6970},
  doi = {10.3390/s26216970}
}
Kostenlos starten →