Improving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection
Sensors · 31.10.2026 · 26 (21) · 6912
DOI: 10.3390/s26216912 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 31.10.2026. Verfasst von Pietro Chierico und 5 weiteren Autor:innen. Beteiligte Einrichtung: BioMIT.org, Electronic Engineering Department, Universitat Politècnica de València, 46022 Valencia, Spain. Hauptthemen laut MEDLINE: Photoplethysmography, Heart Rate, Wearable Electronic Devices. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Spanish State Research Agency, Spanish Government, European Regional Development Fund.
Abstract (Originalsprache)
Photoplethysmography (PPG) is a widely used, non-invasive technique for heart rate monitoring, but its reliability is often compromised by noise and motion artifacts (MAs). This study presents the Peakwise Correlation Pulse Detector (PCPD), an algorithm for detecting heartbeats directly from PPG signals without requiring electrocardiogram (ECG) signals during operation, evaluated here under clean and controlled synthetic pulse-free-noise conditions. PCPD follows a five-step pipeline: (1) signal segmentation with overlap, (2) sliding cross-correlation using high-quality heartbeat templates, (3) computation of the Minimum Correlation Curve (MCC), (4) feature extraction with machine learning-based classification, and (5) peak translation with constraint analysis. The method was evaluated on a clean dataset, comprising a newly collected PPG dataset with manually annotated signal quality and the publicly available BIDMC dataset, and on a noisy dataset that augments the clean data with synthetic pulse-free segments generated from band-limited Gaussian noise. This evaluation framework tests heartbeat detectors under ideal conditions and under a controlled non-informative-noise protocol. On clean signals, PCPD achieved balanced precision–recall scores of 99.13% on the proposed dataset (internal performance) and 97.04% on the independent BIDMC dataset. Under added synthetic pulse-free noise, PCPD achieved accuracies of 99.30% and 97.16% on the proposed and BIDMC datasets, respectively. In comparative experiments against eleven benchmark heartbeat detection algorithms, PCPD achieved the best performance among the evaluated implementations under the tested synthetic-noise protocol. These results support PCPD as a promising PPG-only peak detector and motivate further validation under real motion artifacts and for downstream signal quality assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BioMIT.org, Electronic Engineering Department, Universitat Politècnica de València, 46022 Valencia, Spain.
- Benejúzar Health Center, Orihuela Health Department, 03390 Benejúzar, Spain.
- Cardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain.
- Cardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain.
- Research Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain.
ORCID-Profile: Pietro Chierico, Daniel Suárez, Lorenzo Fácila, Fernando Hornero, Raúl Alcaraz, José J Rieta
Förderung
- Spanish State Research Agency
- Spanish Government
- European Regional Development Fund
- Junta de Comunidades de Castilla-La Mancha
- Generalitat Valenciana
Zitieren
APA
Chierico, P., Suárez, D., Fácila, L., Hornero, F., Alcaraz, R., & Rieta, J. J. (2026). Improving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection. Sensors, 26(21), 6912. https://doi.org/10.3390/s26216912
Vancouver
Chierico P, Suárez D, Fácila L, Hornero F, Alcaraz R, Rieta JJ. Improving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection. Sensors. 2026;26(21):6912. doi:10.3390/s26216912
BibTeX
@article{Chierico2026,
author = {Chierico, Pietro and Suárez, Daniel and Fácila, Lorenzo and Hornero, Fernando and Alcaraz, Raúl and Rieta, José J},
title = {Improving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6912},
doi = {10.3390/s26216912}
}
EUVIMED