Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition
Sensors · 28.10.2026 · 26 (21) · 6822
DOI: 10.3390/s26216822 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 28.10.2026. Verfasst von Ali Pourhossein und 1 weiteren Autor:innen. Beteiligte Einrichtung: Age-Appropriate Human-Machine Systems, Institute of Psychology and Ergonomics, Technische Universität Berlin, 10623 Berlin, Germany. Hauptthemen laut MEDLINE: Wireless Technology, Computer Communication Networks. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Reliable multimodal measurement requires coordinated acquisition of physiological and biomechanical signals operating at different sampling rates. A six-node wireless architecture was developed to support seven data streams: three surface electromyography (sEMG) signals (2 kHz each), photoplethysmography (PPG, 400 Hz configured), inertial measurements (416 Hz configured), and independent pinch- and grip-force streams (nominal 80-SPS HX711 mode; measured at 85.1 and 85.9 samples/s, respectively). An ESP32-S3 gateway uses a single ESP-NOW network for sensor-data delivery and continuous per-node clock compensation while preserving raw measurements, sample-level timing metadata, and end-to-end integrity diagnostics. Across three independent 30-min full-system recordings, pooled packet delivery and sample continuity were 99.987% and 99.988%, respectively. External common-input validation between two independent sEMG nodes yielded a drift-compensated timing mean absolute error of 0.0754 ms across 897 accepted events. A separate six-node GPIO reference-pulse test yielded a node-clock alignment mean absolute error of 0.3123 ms across 5319 matched events with 99.49% of events below 1 ms. Network-load and indoor distance tests further characterized communication robustness. These results demonstrate the feasibility and reliability of a unified wireless architecture that integrates heterogeneous multi-rate sensing, continuous clock-drift compensation, preservation of original sensor measurements, and comprehensive data-integrity monitoring for synchronized physiological and biomechanical data acquisition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Age-Appropriate Human-Machine Systems, Institute of Psychology and Ergonomics, Technische Universität Berlin, 10623 Berlin, Germany.
ORCID-Profile: Ali Pourhossein, Charmayne M L Hughes
Zitieren
APA
Pourhossein, A., & Hughes, C. M. L. (2026). Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition. Sensors, 26(21), 6822. https://doi.org/10.3390/s26216822
Vancouver
Pourhossein A, Hughes CML. Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition. Sensors. 2026;26(21):6822. doi:10.3390/s26216822
BibTeX
@article{Pourhossein2026,
author = {Pourhossein, Ali and Hughes, Charmayne M L},
title = {Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6822},
doi = {10.3390/s26216822}
}