EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Edge-Computing Sensor Platform for ISO 2631-1 Whole-Body Vibration Exposure Metrics

Shenshi Jiang iD, Xiaoxiao Bu iD, Jane L Whitelaw iD, Enbang Li iD

Sensors · 2026

DOI: 10.3390/s26185937 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Shenshi Jiang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics and Physics, University of Wollongong, Wollongong, NSW 2522, Australia. Hauptthemen laut MEDLINE: Vibration, Accelerometry. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council, Coal Services Health and Safety Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Timely feedback on whole-body vibration (WBV) exposure requires standardised metrics during measurement, yet many workflows record raw acceleration for offline processing, delaying feedback and increasing the data burden for bandwidth-constrained deployment. This paper presents a sensing node computing ISO 2631-1/AS 2670.1 exposure metrics on-device and transmitting metric records, not waveforms. The node combines an LIS2DH microelectromechanical systems (MEMS) accelerometer with an RP2040 microcontroller to calculate weighted root-mean-square (RMS) acceleration, daily exposure A(8), vibration dose value, maximum transient vibration value and crest factor. Algorithm-level verification showed that the implemented Wk filter reproduced the tabulated ISO 2631-1 response within 1.1% across 0.5–80 Hz. The node was compared under laboratory conditions with a CEM DT-178A datalogger whose 20 Hz recordings were reprocessed through a method-matched causal pipeline. Across ten trials per configuration under vertical excitation in the 6.3 Hz one-third-octave band, mean Z-axis A(8) differences were −4.5% (wired) and −7.9% (wireless). The datalogger’s 20 Hz sampling was included within the comparison chain, and the lower realised Wk gain was consistent with the direction and approximate magnitude of the observed offset. Metric-level telemetry reduced the sustained payload rate by up to four orders of magnitude at the summary cadence, supporting bandwidth-constrained uplinks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

VibrationAccelerometryAlgorithmsHumansMicro-Electrical-Mechanical SystemsEquipment Design

Stichwörter der Autor:innen

AS 2670.1ISO 2631-1Internet of Things (IoT)MEMS accelerometeredge computingexposure metricsfrequency weightingmetric-level telemetrywhole-body vibration

Autor:innen und Institutionen

  • School of Mathematics and Physics, University of Wollongong, Wollongong, NSW 2522, Australia.
  • School of Engineering, University of Wollongong, Wollongong, NSW 2522, Australia.
  • School of Medical, Indigenous and Health Sciences, University of Wollongong, Wollongong, NSW 2522, Australia.

ORCID-Profile: Shenshi Jiang, Xiaoxiao Bu, Jane L Whitelaw, Enbang Li

Förderung

  • Australian Research Council
  • Coal Services Health and Safety Trust

Zitieren

APA

Jiang, S., Bu, X., Whitelaw, J. L., & Li, E. (2026). An Edge-Computing Sensor Platform for ISO 2631-1 Whole-Body Vibration Exposure Metrics. Sensors. https://doi.org/10.3390/s26185937

Vancouver

Jiang S, Bu X, Whitelaw JL, Li E. An Edge-Computing Sensor Platform for ISO 2631-1 Whole-Body Vibration Exposure Metrics. Sensors. 2026. doi:10.3390/s26185937

BibTeX
@article{Jiang2026,
  author = {Jiang, Shenshi and Bu, Xiaoxiao and Whitelaw, Jane L and Li, Enbang},
  title = {An Edge-Computing Sensor Platform for ISO 2631-1 Whole-Body Vibration Exposure Metrics},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26185937}
}
Kostenlos starten →