A Center-of-Pressure Guided Finger-Press Sensor for Cuffless Blood Pressure Estimation
Sensors · 2026
DOI: 10.3390/s26175563 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Farhad Ali Irinel Gul und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science and Engineering, Faculty of Automatic Control and Computers, National University of Science and Technology POLITEHNICA…. Hauptthemen laut MEDLINE: Blood Pressure Determination, Fingers, Blood Pressure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Cuffless blood pressure estimation using the finger-pressing method remains sensitive to improper finger centering and inconsistent contact force, which degrade the accuracy of the oscillometric envelope and PPG signal morphology. This paper details the development of a research prototype that integrates three force sensors and a photoplethysmograph (PPG) sensor to quantify the finger–device interaction. This system is intended as a pre-clinical research tool rather than a clinically validated medical device. We implement a weighted centroid algorithm for center of pressure (CoP) feedback to guide geometric centering, alongside a Hybrid Ridge Regression model to estimate the total contact force. The system was evaluated on a pre-clinical pilot cohort of 48 healthy participants (1274 recordings), comparing inflationary (ramp-up) and deflationary (ramp-down) interaction modalities. Force calibration achieved a mean absolute error (MAE) of 1.2 g, with hardware analysis confirming a limited zero-load baseline drift of −0.29% over 50 days. The best single-recording calibrated model achieved a mean absolute error (MAE) of 5.55 mmHg (systolic) and 5.20 mmHg (diastolic), with a mean error (ME) ± standard deviation (SD) of +0.50±7.25 and +1.19±6.47 mmHg, respectively, in this pilot cohort, demonstrating the feasibility of the three-point force-sensing design with CoP tracking.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Computer Science and Engineering, Faculty of Automatic Control and Computers, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania.
ORCID-Profile: Farhad Ali Irinel Gul, Dan Tudose
Zitieren
APA
Gul, F. A. I., & Tudose, D. (2026). A Center-of-Pressure Guided Finger-Press Sensor for Cuffless Blood Pressure Estimation. Sensors. https://doi.org/10.3390/s26175563
Vancouver
Gul FAI, Tudose D. A Center-of-Pressure Guided Finger-Press Sensor for Cuffless Blood Pressure Estimation. Sensors. 2026. doi:10.3390/s26175563
BibTeX
@article{Gul2026,
author = {Gul, Farhad Ali Irinel and Tudose, Dan},
title = {A Center-of-Pressure Guided Finger-Press Sensor for Cuffless Blood Pressure Estimation},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26175563}
}
EUVIMED