Parallel-Channel PIV System for Time-Resolved Measurement of Shock Wave Reflection and Diffraction
Sensors · 02.08.2026 · 26 (15) · 4866
DOI: 10.3390/s26154866 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 02.08.2026. Verfasst von Tianqing Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Conventional particle image velocimetry (PIV) techniques face an inherent trade-off between temporal resolution and single-pulse laser energy, limiting their performance in shock wave measurements. This study develops a multi-channel parallel PIV system with programmable timing control to address this constraint. By distributing laser pulses across eight independent optical channels, the system decouples single-pulse energy from the repetition rate, enabling continuous velocity field measurements at microsecond temporal resolution with high signal-to-noise ratio. Experiments were conducted on a planar shock wave propagating over a trapezoidal step in a shock tube facility. The system captured velocity fields at seven consecutive time instants with a 1 μs pulse interval, revealing the curved evolution of diffracted shock fronts and transient flow separation induced by shock–boundary-layer interaction. Comparison with unsteady Reynolds-averaged Navier–Stokes simulations demonstrated that the PIV system resolves fine-scale post-shock perturbations and turbulent fluctuations that were numerically dissipated in computational fluid dynamics. The results verify that the parallel-channel architecture accurately captures unsteady flow structures during shock reflection and diffraction, offering a reliable diagnostic technique for investigations of shock wave dynamics.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China.
ORCID-Profile: Tianqing Zhao
Zitieren
APA
Zhao, T., Wu, Z., Yang, J., Guan, J., Li, J., & Li, G. (2026). Parallel-Channel PIV System for Time-Resolved Measurement of Shock Wave Reflection and Diffraction. Sensors, 26(15), 4866. https://doi.org/10.3390/s26154866
Vancouver
Zhao T, Wu Z, Yang J, Guan J, Li J, Li G. Parallel-Channel PIV System for Time-Resolved Measurement of Shock Wave Reflection and Diffraction. Sensors. 2026;26(15):4866. doi:10.3390/s26154866
BibTeX
@article{Zhao2026,
author = {Zhao, Tianqing and Wu, Zutang and Yang, Jun and Guan, Junyi and Li, Jin and Li, Guoliang},
title = {Parallel-Channel PIV System for Time-Resolved Measurement of Shock Wave Reflection and Diffraction},
journal = {Sensors},
year = {2026},
volume = {26},
number = {15},
pages = {4866},
doi = {10.3390/s26154866}
}
EUVIMED