EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Electrical Anisotropy on Apparent Resistivity Responses in Tunnel Advance Detection: A Three-Dimensional Forward Modeling Study

Qian Liu, Mingxin Yue iD, Chao Chen, Kun Yang

Sensors · 22.07.2026 · 26 (14) · 4653

DOI: 10.3390/s26144653 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 22.07.2026. Verfasst von Qian Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Transportation Engineering, Nanjing Tech University, Nanjing 211816, China. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, Xuzhou 221116, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Water-bearing faults pose critical hazards in tunnel excavation due to sudden water inrush, making reliable advance detection essential. This study presents a systematic forward modeling framework that integrates COMSOL Multiphysics and MATLAB to simulate three-dimensional direct current (DC) responses ahead of the tunnel face. A three-dimensional finite-element model was developed to investigate the influence of electrical anisotropy on apparent resistivity under controlled geological conditions. Electrical anisotropy of both surrounding rock and water-bearing faults is incorporated to evaluate its influence on apparent resistivity. Numerical experiments investigate the effects of surrounding-rock and fault anisotropy and reveal the mechanism behind hourglass-shaped low-resistivity anomalies. The results also reveal systematic biases when anisotropy is neglected, including forward-shifted anomaly positions, overestimated lateral extents, and more diffuse anomaly boundaries. When anisotropy is considered in both the surrounding rock and the fault, the simulated anomaly closely matches the preset fault location, demonstrating improved localization accuracy. The modeling results clarify the effects of key parameters on apparent resistivity responses and improve the interpretation of low-resistivity anomalies. They also provide a theoretical basis for enhancing the reliability of DC resistivity-based tunnel advance detection.

Schlagwörter

Stichwörter der Autor:innen

apparent resistivitydirect current methodelectrical anisotropyelectrode layoutforward modelingtunnel advance detectionwater-bearing faults

Autor:innen und Institutionen

  • School of Transportation Engineering, Nanjing Tech University, Nanjing 211816, China.
  • State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, Xuzhou 221116, China.
  • College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
  • College of Mechanical Engineering, Taiyuan University of Technology, Taiyuan 030024, China.

ORCID-Profile: Mingxin Yue

Förderung

  • State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, Xuzhou 221116, China

Zitieren

APA

Liu, Q., Yue, M., Chen, C., & Yang, K. (2026). Influence of Electrical Anisotropy on Apparent Resistivity Responses in Tunnel Advance Detection: A Three-Dimensional Forward Modeling Study. Sensors, 26(14), 4653. https://doi.org/10.3390/s26144653

Vancouver

Liu Q, Yue M, Chen C, Yang K. Influence of Electrical Anisotropy on Apparent Resistivity Responses in Tunnel Advance Detection: A Three-Dimensional Forward Modeling Study. Sensors. 2026;26(14):4653. doi:10.3390/s26144653

BibTeX
@article{Liu2026,
  author = {Liu, Qian and Yue, Mingxin and Chen, Chao and Yang, Kun},
  title = {Influence of Electrical Anisotropy on Apparent Resistivity Responses in Tunnel Advance Detection: A Three-Dimensional Forward Modeling Study},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {14},
  pages = {4653},
  doi = {10.3390/s26144653}
}
Kostenlos starten →